XX163-11-00 Rev 1006 SVFT-PRS Pressurized Dome Housing
Installation
•
11
Pipe Mount Method
Use this method to install, wire and
configure a pipe mounted unit. Refer to
Figure 6.
Installing the Pipe Mount
1. Select a suitable mounting location
and verify that the site wiring is
present.
Caution: Mount only to installed pipes
with sufficient strength to support the
mount and unit and as vertically level as
possible.
2. Install a vertically hung 1-1/2 in.
(38 mm) diameter NPT schedule 40
pipe with a coupling on the end.
3. Using the provided sealant stick, apply
generously around the threads.
4. Place the pipe mount on the thread
and turn it clockwise, by hand, until it
fits snugly. Orient the service cover to
a convenient position.
5. Tighten the two set screws on the
neck of the mount using a hex key if
additional security is desired.
Figure 6
Pipe Mount Installation
Summary of Contents for SVFT-PRS22E
Page 2: ......
Page 16: ...10 Installation XX163 11 00 Rev 1006 SVFT PRS Pressurized Dome Housing...
Page 31: ......