XX074-02-01 Rev 703 Variable-Speed Keypad 

Operation  

  11 

9

9

9

9

Adding All Cameras

Press

Press

SEQ

Press

1

Press & Hold

PROG

Release

PROG

 

 

9

9

9

9

Deleting All Cameras

Press

Press

SEQ

Press

2

Press & Hold

Perform these steps if you

are not already in Mode 2.

PROG

Release

PROG

 

 

Using the Joystick 

Panning and Tilting

Use the joystick. 
Deflect the joystick 
farther in the 
desired direction to 
increase speed.

Autopanning

Note: Manual pan operations 
have priority over the autopan 
function. Panning during 
autopanning will deactivate 
autopanning.

Toggle the 
A/P button to 
start or stop 
autopanning.

A/P

Zooming with the Joystick

V1411J-DVC Only:
Twist clockwise for Zoom In.
Twist counterclockwise for 
Zoom Out.

Setting Autopan Speed Control

Note: This procedure is for Surveyor series domes only using 1300 speed control type. 

Note: For receivers other than the Surveyor series domes, use the procedure below to set the autopan speed.

Deflect the joystick to the desired 
position. This position determines 
the speed (the farther away from 
center, the faster the speed).

During autopanning, press 
A/P up to four times to step 
through available speeds.

Press & Hold

A/P

A/P

To stop autopanning, 
press the A/P key a 
fifth time.

Use the joystick 
to manually pan 
or tilt.

A/P

A/P

Release

Release

then...

OR

Changing the Joystick Speed

Press to toggle between 
the maximum joystick 
speed and 1/4th of the 
maximum speed. This 
allows you to easily track 
a slow moving object.

P/T

SPEED

Press

 

Summary of Contents for V1410X-DVC

Page 1: ...800 287 1207 WEB www vicon cctv com Vicon Industries Inc does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free...

Page 2: ......

Page 3: ......

Page 4: ...Passcode Setup 5 Keypad Setup 6 Operation 8 Operating Modes 8 Alarms 8 Auxiliary Function Control 8 Communication Failure 9 Crosspoint Reset 9 Lens Operation 9 Presets 9 Manual Switching 10 Salvos and...

Page 5: ......

Page 6: ...EN61000 3 3 1995 and Immunity EN50130 4 1995 and A1 1998 The keypad operates as a standalone controller for dome receivers without the need for matrix switchers or in a multi keypad installation using...

Page 7: ...a 9 VAC power supply is included The two leads will be connected to the RJ 45 termination box You may connect the two leads to either of the termination box screws shown in the figures to follow polar...

Page 8: ...box screws shown below polarity is not a factor for either the DC or the AC supply 110 VAC or 230 VAC NOVA Control System Distribution Line Control VICON V1400X IDL POWER CPU 10 9 8 7 6 5 4 3 2 1 STA...

Page 9: ...ct all like signals for example connect Command In on the first keypad s RJ 45 box to Command In on the second keypad s termination box and so forth V1411X DVC V1411X DVC RJ45 to RJ45 CABLE 110 VAC or...

Page 10: ...e 2 New Passcode 5 Passcodes 2 11 are for users Enter the 4 digit passcode for the first user press A P to save the passcode and continue to set up passcodes if needed Note that you do not have to use...

Page 11: ...address each keypad must have a unique address After you have set up the keypad completely power your control system and refer to its documentation to set the Keypad State to Auto in the control syst...

Page 12: ...Off Key Click Audible indicator for key presses On Off Preset 1 On Alarm Recalls preset 1 home on the receiver in an alarm state Standalone mode only On Off Alarm Slf Clr Alarm Self Clear Automatical...

Page 13: ...ss CANCEL or SEQ to step through active alarms SEQ will step you through the alarms from the first active alarm to the last active alarm CANCEL will step you through the alarms from the first active a...

Page 14: ...ized A P Controlling the Lens Zoom Focus Iris Lens Speed Toggle key to automatically adjust to ambient lighting conditions or deactivate Note that autoiris operation has priority over manual iris cont...

Page 15: ...Tour Enter tour number Press SEQ at any time to run the quick access tour Press Cancelling a Running Tour or Salvo Press Use the joystick to move to a new position CANCEL Sequential Switching Note Seq...

Page 16: ...VC Only Twist clockwise for Zoom In Twist counterclockwise for Zoom Out Setting Autopan Speed Control Note This procedure is for Surveyor series domes only using 1300 speed control type Note For recei...

Page 17: ...umerical Keypad Camera monitor selection dwell time input mode selection etc Camera Key Assigns selected camera to selected monitor Monitor Key For monitor selection enabling Cancel Key Used to clear...

Page 18: ...V 2288 For service or returns from countries in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to...

Page 19: ...Europe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32...

Reviews: