Scanner With Control
1. Energize the control and check that the
switch is not energized.
2. Press MANUAL RIGHT switch on control and hold until
the scanner rotates to the desired right-hand position.
Release pushbutton.
3. Install the right limit stop (2 on Figure 2) just to the right of
the switch actuator (4) by pushing it into the groove until
it snaps in place.
4. Press MANUAL LEFT on control and hold until the
scanner rotates to the desired left-hand position.
Release pushbutton.
5. Install the left limit stop (3) to the left of the switch
actuator as in step 3.
6. Mount camera on scanner. Refer to MOUNTING THE
CAMERA Section.
7. With both limit stops securely snapped in place, pan to
both stop positions and recheck for exact trim.
Scanner With Line Cord Option
Plug line cord into AC outlet
2. Allow unit to
to desired right-hand position. Un-
plug cord.
3. Install the right limit stop (2 on Figure 2) just to the right of
the switch actuator (4) by pushing it into the groove until it
snaps in place.
VIEW A-A
2
Right Limit Stop
3 Left Limit Stop
4 Switch Actuator
Hex-head Screws (2)
6 Camera Mounting Holes
Figure 2
Limit Stop Adjustments
4. Plug in the line cord and allow the unit to
to
desired left-hand position. Unplug cord.
5. Install the left limit stop (3) to the left of the switch actuator
as in step 3.
6. Mount camera on scanner. Refer to MOUNTING THE
CAMERA section.
7. With both limit stops securely snapped in place, energize
the scanner and check for exact trim.
MOUNTING THE CAMERA
CAUTION: Do not mount an
lens on an autopanning
unit. Such use will cause excessive wear on the iris
mechanism
as
it constantly compensates for different light
levels.
Use a
screw and lockwasher to mount the camera.
To obtain the best balance, this screw must be placed in one
of three positions provided (6 on Figure 2). A simple method
to determine camera balance is to place a pencil under the
camera on a flat surface. Move the camera until it balances
on the pencil. The position of the pencil under the camera
then indicates the point which should be at the center of the
mounting place.
The scanner has an off-center pivot on the camera mounting
platform which allows the camera tilt angle to be adjusted
from 10 degrees above the horizon line to 90 degrees below,
or from 10 degrees below the horizon line to 90 degrees
above depending on camera mounting (see Figure 3). To
adjust camera tilt angle at the pivot point, loosen the hex-head
screws (5 on Figure 2) on each side of the camera mounting
bracket and tilt the bracket to the desired position. Retighten
the two screws firmly. The
Series units have an
additional pan head screw on each side of the bracket.
Loosen for adjustment, then retighten.
OPERATION
Scanners used with a line cord option
do not use
a control unit. They operate automatically when connected
to the appropriate supply circuit. Other units are energized
through the main power switch on the control unit. For de-
tailed operating instructions refer to the
instruction
sheet supplied with scanner control.
MAINTENANCE
These scanners are permanently lubricated and do not re-
quire regular maintenance.
REPAIR
Repairs should be attempted only by skilled personnel in an
adequately equipped facility. See Figure 4 through
for
Schematic Diagrams and Replacement Parts List.
4
X328-885