6.1.6 Video Loss Alarm
When an alarm input is generated, the relevant camera image appears as a full screen image.
For a generated alarm, the sequence of operation is:
1.
MON output and VCR output are changed to display the full screen image of alarmed channel.
2.
VCR output is changed to the same as MON output.
The VD LOSS remains in the alarm mode for the duration of the alarm.
6.1.7 Freeze Frame Function
This function enables you to freeze one channel of the 4 video channels on a full-screen mode by pressing
the numeric key of the selected channel on front panel.
To return to the previous mode, press the same numeric key.
6.1.8 Computer Remote Control
V4400QS-1 uses a very simple command set, each command consisting of three characters. The first
character in all cases is the slash or virgule (/). The unit looks only for a three-character command, with an
initial slash. It ignores all other characters. If a mistake is made in entering a command, just type in another
slash character followed by the appropriate character for the desired command. The commands are listed in
the Table 3, RS-232 Commands.
Signal Format is as follows:
1. Data Format: 1,200 Baud/8 Data Bit/No Parity/One Stop Bit.
2. Mode: Half Duplex Mode (Not Echo Received Character).
Table 3
RS-232 Commands
COMMAND RS-232
CODE
RS-232
Pin-out
VCR input /VR Pin 1 Not Used
Enter
the
programming
mode /ME
Pin
2 RS-232
In
Sequence/Reset /SR
Pin
3-4 Not
Used
Camera 1/Up /1U Pin 5 GND
Camera 2/Down /2D Pin 6-9 Not Used
Camera
3/Left /3L
Camera
4/Right /4R
Quad
display/Enter
/QE
PIP /PI
6.1.9 Factory Default Settings
You can restore the unit to its factory default settings as follows:
!
Press and hold the
QUAD/ENTER
key and plug in the power cord (turn on power). This restores the
unit to its initial values.
The initial Factory Default values are as follows:
!
CAMERA TITLES - Display as “CH1”, “CH2”, “CH3”, “CH4”.
10