38
Send Alarm
Message by FTP/E-Mail
The administrator can select whether to send warning messages by FTP
and/or E-mail when motion is detected.
Upload Image by FTP
Select this item and the administrator can assign an FTP site and
configure various parameters. When motion is detected, event images
will be uploaded to the appointed FTP site.
<Pre-trigger buffer> function allows users to check what caused the
trigger. The <Pre-trigger buffer> frame rate can be pre-determined;
<Post-trigger buffer> is for users to upload certain amount of images
after motion event occurs.
NOTE:
Normally the setting range of the <Pre-trigger buffer> is 1
to 20. However, the setting range will change accordingly if the
frame rate of MJPEG on the <Video Frame Rate> setting page is
6 or smaller.
Check the box <Continue image upload> to upload the triggered images
during for a designated amount of time or keep uploading until the
trigger is off. Select <Upload for __ sec> and enter the duration in the
blank. The images of the duration will be uploaded to FTP when the
motion event occurs. The setting range is from 1 to 9999 seconds.
Select <Upload during the trigger active> to have the images continually
uploaded to FTP during the trigger active until the event stops. Set the
Image frequency as the upload frame rate. The setting range is from 1
frame to 15 frames.
NOTE:
Make sure FTP configuration has been completed. Refer
to section
FTP
for further details.