DISPLAYING THE POWER LOSS LIST (POWER LOSS LIST)
POWER LOSS LIST
Turn the JOG dial to select “Power Loss List.” Turn the SHUTTLE ring to the right to display the Power
ALARM LIST
ALL MENU INITIALIZE
Loss List. Power failure start times are stored in memory, so it is possible to confirm when they have
POWER LOSS LIST CLEAR
occurred. Up to 3 power failure start times will be displayed. If more than 3 failures have occurred, the
first and the last 2 power failure start times will be displayed,
DISPLAYING THE ALARM LIST (ALARM LIST)
ALARM LIST CLEAR
<REPEAT REC TIMES>
TIME>
Turn the JOG dial to select “Alarm List.” Turn the SHUTTLE ring to the right to display the Alarm List. Alarm record start limes are
stored in memory, so it is possible to confirm when they have occurred. Up to 3 alarm record start times will be displayed. If more
than 3 alarm records have occurred, the first and the last 2 alarm record start times will be displayed.
INITIALIZING ALL MENU SETTINGS (ALL MENU INITIALIZE)
Turn the SHUTTLE ring to the right and “ALL MENU INITIALIZE” will be displayed. When the SHUTTLE ring is turned to the left,
each setting is initialized except
RECORDING setting. When the SHUTTLE ring is turned to the right, the “MAINTENANCE”
menu will be displayed.
POWER LOSS LIST CLEAR (POWER LOSS LIST CLEAR)
Turn the SHUTTLE ring to the right and “POWER LOSS LIST CLEAR” will be displayed. When the SHUTTLE ring is turned to the
left, the Power Loss List is cleared. When the SHUTTLE ring is turned to the right, the “MAINTENANCE” menu will be displayed.
ALARM LIST CLEAR (ALARM LIST CLEAR)
Turn the SHUTTLE ring to the right and “ALARM LIST CLEAR” will be displayed. When the SHUTTLE ring is turned to the left, the
alarm list is cleared. When the SHUTTLE ring is turned to the right, the “MAINTENANCE” menu will be displayed.
<FIRST TIME SET UP>
1
SETTING THE OPERATION WHEN THE TAPE REACHES THE END (TAPE END)
D TAPE
STOP
Sets the state of operation of the VCR when the tape runs out during recording.
QUASI V-SYNC
TAPE LENGTH
STOP:
The tape stops. “End” will appear on the fluorescent display and
End” will appear on
PB HEAD SELECT
NORMAL
the monitor. When “CALL OUT” is set to
END”, a CALL signal is output from
BUZZER
WRNG
TIME DATE ADJUST
the CALL terminal.
REWIND: Rewinds the tape to the beginning and stops (except during timer recording).
When “CALL OUT” is set to
END”, a CALL signal is output for 2 seconds from the CALL terminal.
REPEAT Rewinds the tape to the beginning and resumes recording.
PROTECTION):
If alarm recordings are present on the tape, then the tape stops. “End” will appear on the fluorescent display and “Tape
End” will display on the monitor, When “CALL OUT” is set to
END”, a CALL signal is output from the CALL
terminal. If there are no alarm recordings, the tape is rewound and recording continues.
2
SETTING QUASI-V-SYNC (QUASI V-SYNC)
Sets Quasi-V-Sync on or off.
ON:
Quasi-V-Sync signal is inserted on the video output signal when in the special playback modes (still, slow motion, reverse,
fast playback, speed search) and during normal playback in
24H 168H or OH mode.
OFF:
Quasi-V-Sync signal is not inserted.
Some
may require the Quasi-V-sync OFF in order to work properly.
3
SETTING THE TAPE LENGTH (TAPE LENGTH)
Sets the tape length to match the tape so that the Tape Remaining Indicator operates correctly.
T-120: When using T-120 tape
T-160: When using T-160 tape
4
SETTING THE HEADS FOR PLAYBACK (PB HEAD SELECT)
Sets the heads for playback. When the JOG dial is turned to the right, the display will be switched in the order of NORMAL
R/R (RIGHT/RIGHT)
AUTO
NORMAL
. . .
l
This VCR is equipped with two pairs of SP heads. Some VCRs make Time Lapse recordings using same Azimuth heads which are
not VHS compatible. Playback of such tapes with the Normal setting will have picture/noise with a 30 Hz flicker, or just noise. To
obtain proper playback, adjust the setting to AUTO, or set to
or
One setting will provide normal play. After playing a tape
with
or R/R settings, return the setting to Normal.
5
SETTING THE BUZZER ON/OFF (BUZZER)
Sets the conditions for which the buzzer sounds.
W R N G
The buzzer sounds when there is any malfunction in the VCR.
END
The buzzer sounds when there is any malfunction in the VCR or at the tape end.
: The buzzer sounds when there is any malfunction in the VCR or when the tape (T-120 or T-160) has
approximately 3 minutes left in 2H mode.
OFF
: The buzzer does not sound.
6
SETTING
THE PRESENT TIME, DATE AND DAYLIGHT SAVING TIME SETTINGS (TIME DATE ADJUST)
Refer to the pages 16 17.