ALARM RECORDING
It is possible to switch from all recording modes to the 2H
recording mode by applying an alarm signal to
the SET IN terminal on the rear panel.
ALARM SET INPUT
a
l
It is possible to switch to the alarm recording by
OH
2H
2H
O H
applying the set signal from the alarm sensor
RECORDING RECORD. RECORDING
R E C O R D I N G
during recording in
48H
168H or OH mode.
ALARM mode I
NORMAL mode
Set the alarm recording mode and alarm recording period with the “RECORDING SET UP” menu. (See page 12.)
The index signal is automatically recorded when an alarm recording begins. (INDEX indicator flashes on the fluorescent
display.)
To
record the index signal, the first 15 seconds of the alarm recording are in 2H or 6H mode.
While the index signal is being recorded (for 15 seconds), if another set signal is applied to the SET IN terminal, it will not
trigger a new alarm recording.
External alarm lamp
l
The alarm can be confirmed from a distance
by connecting the ALM (ALARM) OUT
terminal to an existing alarm system panel or
other external devices such as a buzzer.
Alarm reset switch
.
1st VCR
2nd VCR
If the “ALARM REC DURATION” of the “RECORDING SET UP” menu is set to other than “MAN
the on-screen clock Can
be reset to the nearest hour, by applying a signal to the RST IN terminal. For example, if the current time is
be reset to
and if the current time is
it will be reset to 12:OO:O0.
When connecting the MODE terminal of the 1 st VCR with RST (RESET) IN terminal of the 2nd VCR and if the “MODE
OUT” of the “REAR TERMINAL” menu
is set to “CLOCK
the on-screen clock of the 2nd VCR will
be
to that of the 1 st VCR.
2 5