background image

13

Advanced Functions

Reference page

<MAIN MENU>

DISPLAY

TIMER PROGRAM

RECORDING SET UP

REAR TERMINAL

MAINTENANCE

<RECORDING SET UP>

ALARM REC MODE

6H

ALARM REC DURATION

1M

EMERGENCY REC

OFF

CLOG DETECT

ON

SUPER RESOLUTION

ON

ALARM REC DURATION

1M

EMERGENCY REC

OFF

CLOG DETECT

 ON

SUPER RESOLUTION

ON

ONE SHOT•FIELD

1

ONE SHOT•INTERVAL

10S

ALARM REC DURATION

1M

EMERGENCY REC

OFF

CLOG DETECT

 ON

SUPER RESOLUTION

ON

ONE SHOT•FIELD

5

ONE SHOT•INTERVAL

10S

EMERGENCY REC

OFF

CLOG DETECT

 ON

SUPER RESOLUTION

ON

ONE SHOT•FIELD

5

ONE SHOT•INTERVAL

10S

One shot/Interval Recording

One shot recording allows you to control the number of fields to
be recorded when the REC button is pressed or the REC IN
terminal is grounded.  Interval recording is made at the selected
number of fields and at the selected interval.

1. Press REC/PLAY MODE button on the front panel to set the

recording mode to 0H.

2. Press MENU button.

<MAIN MENU> appears.

3. Turn JOG to select RECORDING SET

UP and turn SHUTTLE to the right.

<RECORDING SET UP> menu
appears.

4. Turn JOG to select ONE SHOT•FIELD

and turn SHUTTLE to the right.

5. Turn JOG to select the number of

recording field and turn SHUTTLE to
the right.

6. Turn JOG to select ONE

SHOT•INTERVAL and turn SHUTTLE
to the right.

For one shot recording, setup step 7 only:

7. Turn JOG to select SHOT and turn

SHUTTLE to the right.

For interval recording, setup step 8 only:

8. Turn JOG to select the recording

interval and turn SHUTTLE to the right.

9. Press REC button.

The one shot recording will be on standby mode.

The VCR starts the interval recording with the interval time
selected in step 6 above.

10. To start one shot recording, press REC button again or switch

the REC IN terminal on the rear panel to the ground.

EMERGENCY REC

OFF

CLOG DETECT

 ON

SUPER RESOLUTION

ON

ONE SHOT•FIELD

5

ONE SHOT•INTERVAL

SHOT

EMERGENCY REC

OFF

CLOG DETECT

 ON

SUPER RESOLUTION

ON

ONE SHOT•FIELD

5

ONE SHOT•INTERVAL

30S

Remote Recording

This function permits you to control the start/end of recording
from the remote place.  The VCR starts recording while the REC
IN terminal is grounded.

1. Display <REAR TERMINAL> menu.

2. Set REC IN to REC-START/STOP.

3. Press MENU button.

The day and present time display
appears on screen.

page 21 for remote recording connection.

Note

An index signal will not be recorded during remote recording.

Series or timer recording function cannot be used with remote
recording at the same time.

Repeat Recording

With this function, when the tape reaches its end during
recording, the VCR rewinds the tape and starts recording again.

1. Press MENU button.

<MAIN MENU> appears.

2. Turn JOG to select CLOCK/FIRST

TIME SET UP and turn SHUTTLE to
the right.

<FIRST TIME SET UP> menu
appears.

3. Turn JOG to select TAPE END and turn

SHUTTLE to the right.

4. Turn JOG to select REPEAT or

ALARM•PROT and turn SHUTTLE to
the right.

Refer to the table below for REPEAT
and ALARM•PROT.
Repeat indicator (

) illuminates on

the fluorescent display.

5. Press MENU button.

The day and present time display appears on screen.

<REAR TERMINAL>

CALL OUT

WRNG•TAPE END

CLOCK OUT

REC- 1

MODE OUT

REC

REC IN

REC-START/STOP

<MAIN MENU>

DISPLAY

TIMER PROGRAM

RECORDING SET UP

REAR TERMINAL

MAINTENANCE

CLOCK/FIRST TIME SET UP

<FIRST TIME SET UP>

TIME DATE ADJUST

TAPE END

STOP

QUASI V-SYNC

ON

VIDEO MODE

AUTO

TAPE LENGTH

T-120

BUZZER

WRNG

<FIRST TIME SET UP>

TIME DATE ADJUST

TAPE END

STOP

QUASI V-SYNC

ON

VIDEO MODE

AUTO

TAPE LENGTH

T-120

BUZZER

WRNG

<FIRST TIME SET UP>

TIME DATE ADJUST

TAPE END

REPEAT

QUASI V-SYNC

ON

VIDEO MODE

AUTO

TAPE LENGTH

T-120

BUZZER

WRNG

TAPE END

setting

REPEAT

REWIND

ALARM•

PROT

STOP

The tape stops.

When there are alarm
recordings on tape

When there is NO alarm
recording on tape

The tape stops.(*)

The tape is rewound
automatically to the
beginning and then
recording is resumed.

The tape is rewound automatically to the
beginning (except in timer recording) and
then stops.

The tape is rewound automatically to the
beginning and then recording is resumed
(also recording over existing alarms).

When the tape reaches its end during recording

The following functions are automatically engaged when the tape
ends during recording.

*

To repeat recording on the same tape again, eject the tape
once and reinsert.

Summary of Contents for VCR407

Page 1: ...USTRIES INC 89 ARKAY DRIVE HAUPPAUGE NY 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 24 Hour Technical Support 800 34 VICON 800 348 4266 TOLL FREE 800 645 9116 U K 44 0 1489 566300 Web address ww...

Page 2: ...lateral a pour objet de tirer l attention de l utilisateur sur le fait qu il y a des tensions dangereuses non isol es l int rieur de l enceinte du produit qui peuvent tre suffisamment impor tantes pou...

Page 3: ...ounding type plug 13 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention t...

Page 4: ...s and can radiate radio frequency energy and if not in stalled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that in...

Page 5: ...damage PROTECT THE POWER CORD Damage to the power cord may cause fire or shock hazard When unplugging the power cord hold it by the plug only and pull out carefully UNPLUG THE POWER CORD DURING A LONG...

Page 6: ...tment 17 Searching Techniques 18 Counter Memory Stop 18 Skip Search 18 Index Search 18 Time Date Search 19 Installation Connections for Various Functions 20 Connecting with CCTV Camera Monitor and Sen...

Page 7: ...d or bottom button to move it down During an alarm recording or if an warning is displayed on screen the day and present time display cannot be moved If screen images are blurred vertically during sti...

Page 8: ...hen a tape recorded in Super Resolution mode is inserted to the VCR providing SUPER RESOLUTION in RECORDING SET UP menu is set to ON Repeat indicator Illuminates when TAPE END in FIRST TIME SET UP men...

Page 9: ...a tape reaches its end during recording or if there has been a problem during recording Battery Box Battery is stored here Note This VCR contains a special battery Consult your dealer to replace it RE...

Page 10: ...hen ejecting the tape during recording press STOP button once to stop recording and then press EJECT button to unload the tape You cannot eject a tape when all of the VCR s buttons are locked and the...

Page 11: ...ON SUPER RESOLUTION OFF ONE SHOT FIELD 1 RECORDING SET UP ALARM REC MODE 6H ALARM REC DURATION 1M EMERGENCY REC OFF CLOG DETECT ON SUPER RESOLUTION OFF ONE SHOT FIELD 1 RECORDING SET UP ALARM REC MOD...

Page 12: ...160 the playback mode is switched in the order of 8H L24H L40H 64H 96H 128H 160H 224H 0H 8H for a tape recorded in the recording mode longer than 8H mode A tape recorded in SP mode using other VCR ca...

Page 13: ...on the fluorescent display starts flashing 2 Turn JOG to set the hour digits When the flashing item is same as the current time turn SHUTTLE without turning JOG 3 Turn SHUTTLE to the right to make the...

Page 14: ...HUTTLE to the right to select 5 In the DW column turn JOG to select the Day of the Week Turn SHUTTLE to the right to select 6 In the START column turn JOG to select the hour digits of the start time T...

Page 15: ...ight HOLIDAY SET UP menu appears 3 Turn JOG to move the cursor and turn SHUTTLE to the right Each time JOG is turned to the right the cursor moves towards right forward direction 4 Turn JOG to select...

Page 16: ...d VCR only 5 Turn JOG to select REC IN and turn SHUTTLE to the right 6 Turn JOG to select SERIES and turn SHUTTLE to the right 7 Press MENU button The day and present time display appears on screen MA...

Page 17: ...from the remote place The VCR starts recording while the REC IN terminal is grounded 1 Display REAR TERMINAL menu 2 Set REC IN to REC START STOP 3 Press MENU button The day and present time display a...

Page 18: ...CAMERA3 CAMERA1 CAMERA2 CAMERA3 CAMERA1 CAMERA2 V SYNC SWITCHER switching cameras recording start signal VCR1 recording clock out VCR2 recording clock out VCR3 recording clock out VCR Recording time m...

Page 19: ...s on screen Note Up to 3 power failure start times will be displayed If more than 3 failures have occurred the first start time and the last 2 start times will be displayed on the list 01 01 01 MON 00...

Page 20: ...eed search 11 Forward high speed search indicates the playback speed of the recorded tape in 2H mode 15 7 9 5 9 5 2 7 5 6 15 7 3 4 3 2 1 1 Reverse high speed search 2 Reverse speed search 3 Reverse fa...

Page 21: ...G during still picture Turn to the right to forward Turn to the left to reverse To forward frames or fields continuously keep turning JOG during still picture Keep turning to the right to forward fram...

Page 22: ...en you find a picture you wish to view press PLAY button SEARCH FUNCTION COUNTER MEMORY STOP SKIP SEARCH INDEX SEARCH TIME DATE SEARCH Turn the SHUTTLE RING or to execute Press STOP to exit Note The i...

Page 23: ...earches in the forward direction of the tape when DIRECTION is set to FORWARD Searches in the reverse direction of the tape when DIRECTION is set to REVERSE 5 Turn SHUTTLE to the right to start search...

Page 24: ...GND ALM ALM MODE CLK OUT CALL AUDIO VIDEO OUT OUT IN REMOTE IN RESET RST IN REC GND ALM ALM MODE CLK OUT CALL MIC VIDEO OUT AUDIO OUT MIC IN VIDEO IN AUDIO IN SENSOR CCTV CAMERA ALM IN GND VIDEO IN V...

Page 25: ...ALM MODE CLK OUT CALL RST IN REC GND ALM ALM MODE CLK OUT CALL 1 When connecting the MODE OUT terminal of the first VCR with the RST IN terminal of the second VCR the on screen clock of the second VC...

Page 26: ...31 YEAR 2001 TIME 00 00 00 TIME DATE ADJUST DAYLIGHT SAVINGS AUTO MONTH 07 DAY 09 YEAR 2002 TIME 20 25 00 Accurately set the day and present time before timer programming Month Day Year Hour Alarm Re...

Page 27: ...OT FIELD 1 ONE SHOT INTERVAL SHOT REAR TERMINAL CALL OUT WRNG TAPE END CLOCK OUT REC 1 MODE OUT REC REC IN SERIES MAINTENANCE POWER LOSS LIST ALARM LIST ALL MENU INITIALIZE POWER LOSS LIST CLEAR ALARM...

Page 28: ...ect and ENTER LANGUAGE SELECTION The menu which appears on screen offers 3 languages English ENGLISH Spanish ESPA OL or French FRAN AIS This menu appears by pressing MENU button when the VCR is turned...

Page 29: ...OUT Sets the recording mode and the frequency division ratio of clock pulse output from the CLOCK OUT terminal Setting the recording mode during the clock pulse output REC When recording in any mode...

Page 30: ...e recording Go to page 8 for the VCR s function when the tape reaches its end during playback Setting Quasi V sync on or off QUASI V SYNC ON Quasi V sync signal is inserted to the video output signal...

Page 31: ...R407 the clock pulse may be selected to be output every time a field is recorded or once every two fields or every three fields etc This number is called the frequency division ratio FDR and the ratio...

Page 32: ...s Shielded cable MJ 1 2 3 4 5 6 7 8 9 10 11 12 13 62 k 13 k 15 k 16 k 20 k 22 k 27 k 30 k 36 k 43 k 56 k 75 k 100 k SW SW SW SW SW SW SW SW SW SW SW SW SW Position 1 2 3 4 5 6 7 8 EJECT STOP RECORDING...

Page 33: ...40 or more hours per week when using it everyday Make sure the power cord is connected to the outlet for approximately 40 or more hours per week when using it everyday The reserved contents may be era...

Page 34: ...by pressing VERTICAL ADJUST buttons on the front panel The video heads may be clogged Eject the cassette insert it again and wait for more than 5 seconds Repeat this step for 4 to 5 times If you have...

Page 35: ...t 120H 224H or 0H except for 128H mode If it cannot be entirely removed CLOg flashes on the fluorescent display If so follow the remedy of CLOg in the above chart To turn off the indicator Remedy Fluo...

Page 36: ...terminals screw DC 12 V 10 k GND CLK OUT 10 k Interface circuit inside the VCR ALM MODE CALL OUT terminals screw Active L level voltage 0 to 0 4 V output max drive current 50 mA 5 V DC 10 mA 24 V DC...

Page 37: ...pe Speed and Recording See below 1 Fast Forward Rewind Time Approx 120 seconds with T 120 tape Operating Temperature 41 F to 104 F 5 C to 40 C Relative Humidity Max 80 Dimensions Jog dial included 16...

Page 38: ...s in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a N...

Page 39: ...35 Others Reference page...

Page 40: ...FAX 800 287 1207 Vicon Europe Headquarters Brunel Way Fareham PO15 5TX United Kingdom Tel 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Be...

Reviews: