15
Advanced Functions
Reference page
Additional Features
Memory backup in case of power failure
This VCR includes a built-in backup memory, so the preset day
and present time will remain in memory even if there is a power
failure. However, if the power cord is disconnected for a long
period of time (2-3 months), the present time may not be
accurate. In this case, set the clock again.
Info.
•
The battery is fully charged if the VCR’s power cord is plugged
into the outlet for 40 or more hours per week.
•
If the battery is fully charged, even if the power cord is not
plugged in, the following settings will remain in memory for up
to 31 days:
–
The day and present time display
–
Timer program
–
Alarm list/Power loss list
–
Number of tape uses/Elapsed time of the VCR
–
Counter display
–
Recording/Playback mode
Note
•
When ALARM REC DURATION of the RECORDING SET UP
menu is set to MAN1 or MAN2 and a power failure occurs
during the alarm recording, the VCR may not return to the
alarm recording mode when the power comes back on.
After a power failure
If a power failure occurs during manual,
timer or alarm recording, the VCR will
return to the recording mode when the
power comes back on. The Power Failure
symbol (X) will be displayed for about 1
minute on screen and the Power Loss
indicator ( ) will illuminate on the
fluorescent display when the power comes
back on. If a power failure occurs while the
VCR’s power is on, the VCR will turn on by
itself when the power comes back on.
Displaying/clearing the power loss list
Displaying the power loss list
The power failure start time is logged in the VCR’s Power Loss
List. To view the list, please follow the steps listed below.
1. Press MENU button.
•
<MAIN MENU> appears.
2. Turn JOG to select MAINTENANCE
and turn SHUTTLE to the right.
•
<MAINTENANCE> menu appears.
3. Turn JOG to select POWER LOSS
LIST and turn SHUTTLE to the right.
•
<POWER LOSS LIST> appears.
4. Press MENU button.
•
The day and present time appears
on screen.
Note
•
Up to 3 power failure start times will be displayed. If more
than 3 failures have occurred, the first start time and the last 2
start times will be displayed on the list.
01-01-’01 MON
00:00:00 X L30
<MAINTENANCE>
POWER LOSS LIST
ALARM LIST
ALL MENU INITIALIZE
POWER LOSS LIST CLEAR
ALARM LIST CLEAR
<REPEAT REC TIMES>
0
<ELAPSED TIME>
0H
<POWER LOSS LIST>
01 01-31-’01 00:00
02
03
Clearing the power loss list
1. Select POWER LOSS LIST CLEAR in
<MAINTENANCE> menu and turn
SHUTTLE to the right.
2. Turn SHUTTLE to the left to clear the
list.
•
<MAINTENANCE> menu appears.
To exit the menu without clearing
the list, press MENU button.
3. Press MENU button.
•
Once the list is cleared, the Power Loss indicator ( ) will
go off.
Displaying/clearing the alarm list
Displaying the alarm list
The alarm recording start time/date are logged in the VCR’s
Alarm List. To view the list, please follow the steps listed below.
1. Press MENU button.
•
<MAIN MENU> appears.
2. Turn JOG to select MAINTENANCE
and turn SHUTTLE to the right.
•
<MAINTENANCE> menu appears.
3. Turn JOG to select ALARM LIST and
turn SHUTTLE to the right.
•
<ALARM LIST> appears.
4. Press MENU button.
•
The day and present time appears
on screen.
Note
•
Maximum of 9,999 alarm recording start times will be
counted.
•
Up to 8 alarm recording start times/dates will be displayed. If
more than 8 alarm recordings have occurred, the first start
time and the last 7 start times will be displayed on the list.
Clearing the alarm list
1. Select ALARM LIST CLEAR in
<MAINTENANCE> menu and turn
SHUTTLE to the right.
2. Turn SHUTTLE to the left to clear the
list.
•
<MAINTENANCE> menu appears.
To exit the menu without clearing the list, press MENU
button.
3. Press MENU button.
•
Once the list is cleared, the Alarm Recording indicator
(
) on the fluorescent display will go off.
POWER LOSS LIST CLEAR
Turn the SHUTTLE RING
then POWER LOSS LIST
will be cleared.
<MAINTENANCE>
POWER LOSS LIST
ALARM LIST
ALL MENU INITIALIZE
POWER LOSS LIST CLEAR
ALARM LIST CLEAR
<REPEAT REC TIMES>
0
<ELAPSED TIME>
0H
<ALARM LIST>
0001
01-31-’01
00:00
0002
0003
0004
0005
0006
0007
0008
ALARM LIST CLEAR
Turn the SHUTTLE RING
then ALARM LIST will be
cleared.
Summary of Contents for VCR407
Page 39: ...35 Others Reference page...