SETTING THE MENUS
2 SETTING THE FREQUENCY DIVISION RATIO (CLOCK OUT)
Sets the frequency division ratio of the CLOCK OUT terminal.
First, set the recording mode for the “CLOCK OUT” pulse output in the “REAR TERMINAL” menu.
REC:
When recording in any mode.
T/L-REC:
When recording in time lapse mode
960H or OH).
Second, select the frequency division ratio setting by turning the SHUTTLE ring. When the JOG dial is turned, the display
will be switched in the order of 1 2 3 4 5 10 15 20 25 30 50 60 F (field) 1 . . . The
numbers from 1 to 60 indicate the number of frames in 2H or 6H recording mode or the number of fields in time lapse
recording mode. (One frame consists of two fields.) One field is selected when it is set to
(field).
3 SETTING THE OPERATION MODE OF THE MODE OUTPUT TERMINAL (MODE OUT)
Sets the state in which the signal output at the MODE OUT terminal is switched to the active condition. When the JOG
dial is turned, the display will be switched on in the order of REC(recording) PLAY(playback) POWER (power “ON”)
TAPE IN (tape is inserted) TAPE REMAIN (3 minutes in 2H mode before the tape end) CLOCK ADJ (output the
signal for 1 second when the clock indicates
REC
4
SETTING THE OPERATION MODE OF THE REC IN TERMINAL (REC
IN)
SERIES
REC-START/ STOP
SYNC REC
:
Recording starts when the REC IN terminal is short-circuited to ground or a
level voltage (0
is applied.
:
Recording starts when the REC IN terminal is short-circuited to ground or a
level voltage (0
is applied. Should this connection be removed, recording will stop.
:
The video signal from 3 or 13 cameras can be recorded separately by connecting a switcher.
(“SYNC
function is available when recording in
or
mode.) Refer to
“SYNCHRONOUS RECORDING” on page 23.
DISPLAYING THE POWER LOSS LIST (POWER LOSS LIST)
POWER LOSS LIST
LIST
Turn the JOG dial to select “Power Loss List”. Turn the SHUTTLE ring to the right to display the
ALL MENU INITIALIZE
Power Loss List. Power failure start times are stored in memory, so it is possible to confirm
when they have occurred. Up to 3 power failure start times will be displayed. If more than 3
failures have occurred, the first and the last 2 power failure start times will be displayed.
POWER LOSS LIST CLEAR
ALARM LIST CLEAR
<REPEAT REC TIMES>
DISPLAYING THE ALARM LIST (ALARM LIST)
Turn the JOG dial to select “Alarm List”. Turn the SHUTTLE ring to the right to display the Alarm List. Alarm record start
times are stored in memory, so it is possible to confirm when they have occurred. Up to 3 alarm record start times will be
displayed. If more than 3 alarm records have occurred, the first and the last 2 alarm record start times will be displayed.
INITIALIZING ALL MENU SETTINGS (ALL MENU INITIALIZE)
Turn the SHUTTLE ring to the right and “ALL MENU INITIALIZE” will be displayed. When the SHUTTLE ring is turned to
the left, each setting is initialized except the TIMER RECORDING setting. When the SHUTTLE ring is turned to the right,
the “MAINTENANCE“ menu will be displayed.
POWER LOSS LIST CLEAR (POWER LOSS LIST CLEAR)
Turn the SHUTTLE ring to the right and “POWER LOSS LIST CLEAR” will be displayed. When the SHUTTLE ring is
turned to the left, the Power Loss List is cleared. When the SHUTTLE ring is turned to the right, the “MAINTENANCE”
menu will be displayed.
ALARM LIST CLEAR (ALARM LIST CLEAR)
Turn the SHUTTLE ring to the right and “ALARM LIST CLEAR” will be displayed. When the SHUTTLE ring is turned to the
left, the alarm list is cleared. When the SHUTTLE ring is turned to the right, the “MAINTENANCE” menu will be displayed.