background image

XX164-60 VF-SR-20/2 Fiber Optic Card Cage and Power Supply 

Functional Description  

  3 

Introduction 

The information in this manual covers the installation of the VF-SR-20/2 Fiber-Optic Card Cage and 
Power Supply. This system should only be installed by a qualified technician using approved materials 
and wiring practices in accordance with the National Electrical Code ANSI/NFPA 70, state, and local 
electrical codes.

 

Read these instructions thoroughly before beginning an installation. 

 

Functional Description 

The VF-SR-20/2 provides rack mounting and power for Vicon fiber-optic rack modules. The VF-SR-20/2 
mounts into a standard EIA 19-inch racking system. It can accommodate up to 14 single slot modules in 
any combination of receivers and transmitters. 
 
The VF-PSR-2 DC power supply is included and supplies a 100 W of output power. It has a universal 
power input of 85 to 264 VAC. For unused slots, a blank panel is available, Model VF-BPS.  

 
Installation 

The VF-SR-20/2 may be mounted, using standard hardware, in an upright position, with the backplane 
upward, inside the cabinet (see diagram below). It is important, as with any electronic equipment, to 
provide sufficient airflow to prevent over heating in the cabinet. At least 1-7/8" (1 RU) of space should be 
allowed above and below the VF-SR-20/2 to provide air flow. If more than one VF-SR-20/2 is installed, 
forced airflow may be necessary depending upon the number of plug-in cards used in the over-all 
installation. It is necessary to add a 1 RU fan unit at the top of every three VF-SR-20/2 racks with 1 U 
spacing between them.  
 
All cards are inserted in a similar manner. Any card may be used in any slot. Insert the card all the way 
until the edge fingers meet the internal bus connector and the front panel is even with the front of the 
rack. Then secure the ¼-turn fasteners by pushing with a small screwdriver, turning the screw 90 
degrees clockwise and releasing pressure. 
 

Power Supply 

The far right hand position of the VF-SR-20/2 is only compatible with a VF-PSR-2 plug-in power supply.  
 
 
 
 

 

VF-SR-20/2 Card Cage and Power Supply 

Summary of Contents for VF-SR-20/2

Page 1: ...ghts reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Hour Technical Support 800 34 VICON 800 348 4266 UK 44 0 1489 566300 WEB www vicon cctv com ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...h can be determined by turning equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Relocate the equipment away from the receiver Plug the equipment into a different electrical outlet so that the equipment and receiver are on different branch circui...

Page 6: ...nters the unit 13 Outdoor Cable Grounding Use only grounded outdoor cables to protect against voltage surges and static charges Section 810 of the National Electrical Code ANSI NFPA 70 1984 provides information on proper grounding of the lead in wire to an antenna discharge unit size of grounding conductors and the requirements of grounding electrodes 14 Lightning Disconnect the product from its p...

Page 7: ...PS Installation The VF SR 20 2 may be mounted using standard hardware in an upright position with the backplane upward inside the cabinet see diagram below It is important as with any electronic equipment to provide sufficient airflow to prevent over heating in the cabinet At least 1 7 8 1 RU of space should be allowed above and below the VF SR 20 2 to provide air flow If more than one VF SR 20 2 ...

Page 8: ...ncludes an exhaust fan In order to insure long life and reliable operation airflow from the fan port should not be obstructed The VF SR 20 2 is supplied with the VF PSR 2 Controls and Indicators Front panel LEDs indicate AC line POWER being present and the power switch being in the ON I position The ON OFF switch is located on the rear of the power supply A front panel LED indicates the AC line be...

Page 9: ...m countries in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem a...

Page 10: ...nsumption Heat Equivalent Radio Emission Standard Power Power Cord Output Connector Indicators Standard hardware Fasteners provided 14 Card Cage Height 5 25 in 133 mm Width 19 in 483 mm Depth 7 6 in 193 mm Card Cage 4 5 lb 2 0 kg Power Supply 2 7 lb 1 2 kg Aluminum Black paint Card Cage Height 12 3 in 312 mm Width 7 7 in 196 mm Depth 20 0 in 508 mm Card Cage Height 3 1 in 77 mm Width 7 0 in 178 mm...

Page 11: ...re not defective or any equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not warrant that such software shall be error bug free Software support via telephone if provided at no cost may be discontinued at any time without notice at Vicon s sole discretion V...

Page 12: ...rs Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1 D 24539 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 47 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Reviews: