VD520 Series Inverter User Manual Product Information
- 9 -
Main Control
Functions
Jogging control
Jogging frequency range: 0.00Hz~max output frequency,
jog Acceleration/down time 0.0s~3600.0s.
Easy PLC,
multi-stage speed
run
Via built-in PLC or control terminal can realize max 16
stage speed run.
Built-in PID
Can realize process control conveniently.
Auto-adjustment
of the voltage
Can keep the output voltage constant automatically when
the grid voltage changed.
Dynamic over
voltage
suppression
Auto suppress energy feedback value while run
frequency changes, prevent bus over current tripping off.
Oscillation
suppression
Optimize V/F oscillation arithmetic, realize V/F steady
operation.
Individual
Function
Power dip ride
through
It ensures that the AC drive continues to run for a short
time when an instantaneous power failure or sudden
voltage reduction occurs.
Timing control
Timing control function: setting time range:
0min-65535min.
Multi-motor
switchover
Two motors can be switched over via two groups of motor
parameters.
Support extension
Support multi-function I/O extension card
Operation
Running
command source
Operation panel, control terminals, serial communication
port, you can perform switchover between these sources
in various ways.
Frequency source
There are a total of 11 frequency sources, such as digital
setting, analog voltage setting, analog current setting,
pulse setting and serial communication port setting, panel
potentiometer setting, you can perform switchover
between these sources in various ways.
Auxiliary
frequency source
There are 11 auxiliary frequency sources, it can
implement fine tuning of auxiliary frequency and
frequency synthesis.
Input terminal
6 digit terminal input, 1 terminal support rapid pulse input
on max 100kHz.
2 analog input terminals; with optional 0/4mA to 20mA
current input or 0V to 10V voltage input.
Extension capacity: 3 digital input terminals and 1 analog
input terminals.
Output terminal
2 analog output terminals; with optional 0/4mA to 20mA
current output or -10V to 10V voltage output.
2 digit output terminals; one supporting
0.01KHz~100KHz square signal rapid pulse output.
2 relay output terminal
Extension capacity: 1 digit output terminal.