Bit13: Length value
Bit14: Load speed display
BIT15: PID setting
F7-03
LED Running
Display
Parameter 2
0000~0xFFFF
Bit00: PID feedback
Bit01: PLC stage
Bit02: PULSE input frequency (kHz)
Bit03: Running frequency 2 (Hz)
Bit04: Set torque (0.%)
Bit05: Voltage before AI1 correction
(V)
Bit06: Voltage before AI2 correction
(V)
Bit07: Reserved
Bit08: Line speed
Bit09: Current power on time (Hour)
Bit10: Current running time (Min)
Bit11: PULSE input frequency (Hz)
Bit12: Communication setting value
Bit13: Reserved
Bit14: Main frequency X display (Hz)
Bit15: Auxiliary frequency Y display
(Hz)
0x0000
○
F7-04
LED Display
Stop Parameter
0000~0x3FFF
Bit00: Set frequency (Hz)
Bit01: Bus voltage (V)
Bit02: DI input state
Bit03: DO output state
Bit04: AI1 voltage (V)
Bit05: AI2 voltage (V)
Bit06: Reserved
Bit07: Count value
Bit08: Length value
Bit09: PLC stage
Bit10: Load speed
Bit11: PID setting
Bit12: Pulse input frequency (kHz)
Bit13: Set torque (0.1%)
0x0033
○
F7-05
The Second
Line LED
Running Display
Parameters
0~15 corresponding bit0~bit15 of
F7-03
16~31 corresponding bit0~bit15 of
F7-04
4
○
F7-06
The Second
Line LED Stop
0~13 corresponding bit0~bit13 of
F7-05
1
○