POWER REQUIREMENTS
DANGER
• ONLY QUALIFIED
ELECTRICIANS SHOULD
CONNECT INCOMING
POWER TO THE TOOL.
• To reduce the risk of electric shock,
check the electrical source for proper
grounding.
• Always turn off the main power supply
to the tool before making any tool
adjustments or before performing any
maintenance.
• DO NOT alter the plug in any way.
Failure to follow these instructions could
result in death or serious personal injury.
The VE460 is designed to operate on a
220/440-volt, 3-phase, 60-Hz power supply.
The tools are shipped with the wiring set for
220-volt operation, unless specified otherwise
on the order. To re-wire the VE460 for 440-volt,
60-Hz service, the following conversions must
be made. Refer to the electrical schematic in the
RP-VE460 Repair Parts List and the information
contained on the nameplate on the tool’s drive
motor and hydraulic pump motor.
Conversions to 440-volt, 60-Hz Service Include:
1.
Motor Connections
2. Fuse Changes
3. Thermal Overload Unit Changes
4. Transformer Connections
The circuit protection required for 220-volt
operation is 20 amps. For 440-volt operation,
15-amp circuit protection is required. All VE460
components are grounded to the frame of the
tool. Make sure the frame is properly grounded.
For other voltages and frequencies, contact
Victaulic.
NOTE:
Operation with certain voltages
(i.e. 380/400 volt, 3-phase, 50/60 Hz service)
requires different motors and other electrical
parts. Contact Victaulic for information regarding
operation of a tool with an alternate voltage.
POWER HOOKUP AND
VERIFICATION OF PIPE
ROTATION DIRECTION
Each VE460 Roll Grooving Tool is provided with
a label inside the main electrical enclosure,
which identifies voltage ratings, etc. for the tool
(refer to example below). Reference must be
made to this label to ensure proper tool setup.
MODEL
VOLTS
PHASE
HERTZ
FULL-LOAD CURRENT
SERIAL NUMBER
208/230
440/460
1
3
380/400
AMPS AT 230 VOLTS
AMPS AT 460 VOLTS
AMPS AT 380 VOLTS
50
60
50/60
• GEAR OIL – AGMA 7
• HYDRAULIC OIL – HIGH-PRESSURE, ANTI-WEAR ISO GRADE 32
• BEARING LUBE – ANTI-WEAR, EXTREME PRESSURE NLGI GRADE 2
3359 Rev
. F
R024268LBL
Electrical Assembly
Drawing Revision Level
VOLTS
PHASE
HERTZ
FULL-LOAD CURRENT
208/230
440/460
1
3
380/400
AMPS AT 230 VOLTS
AMPS AT 460 VOLTS
AMPS AT 380 VOLTS
50
60
50/60
DRIVE MOTOR
HYDRAULIC MOTOR
DANGER
• ONLY QUALIFIED
ELECTRICIANS SHOULD
CONNECT INCOMING
POWER TO THE TOOL.
• The tool must be grounded
properly.
Failure to follow these instructions could
result in death or serious personal injury.
The VE460 Roll Grooving Tool is supplied with
a 3/4-inch nominal conduit opening for wiring
incoming power. The conduit opening is located
at the back of the tool near the main electrical
enclosure.
Incoming electrical connections must be
made inside the main electrical enclosure.
The incoming, three-phase power must be
connected at the top of the main breaker at
the upper-right side within the main electrical
enclosure.
1.
Make the ground connection inside the
main electrical enclosure.
2. Make 3-phase electrical connections to the
circuit breaker of the tool.
3. After the power is connected properly, the
tool must be checked for proper rotational
direction.
TM-VE460_17
TM-VE460
OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.
REV_A