7.
Loosen the knob on the side of the roll
guards to drop the sliding guard onto the
guard setting pad. Tighten the knob.
8. Remove the guard setting pad from the
pipe.
9. When tool guard adjustments are complete,
pull the
“STOP”
knob on the control panel
to the out position.
10. Depress and release the
“HYDRAULIC
PUMP START”
button. The tool’s hydraulic
pump motor will energize and the tool’s
ram shaft will retract to the neutral position.
11. The guard setting procedure is complete.