5a. Grease the stabilizer roller.
5b. Replace the stabilizer roller guard and
stabilizer-roller-guard wing nut.
CHECKING AND FILLING GEAR REDUCER OIL
The gear reducer oil level must be checked
annually. If leakage is present, repairs must be
made to correct the leak.
1.
Remove the oil level plug from the gear
reducer (refer to drawing below). The oil
level should be even with the bottom of the
hole.
Oil Fill Plug
Vent Plug
Oil Level
Plug
2. To add oil, remove the plug from the top of
the gear reducer and fill to the proper level
(refer to drawing above). Refer to the card
attached to the gear reducer for the proper
lubricant.
3. Re-install the plug(s).
CHECKING AND FILLING HYDRAULIC OIL
1.
Check the hydraulic oil level on a monthly
basis. The level should be 1 – 2 inches/25
– 50 mm below the top of the tank. DO
NOT over-fill the tank, since the oil may
overflow due to thermal expansion. Refer to
the applicable “Recommended Lubricants”
table for the proper hydraulic oil.
TM-VE460_47
TM-VE460
OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.
REV_A