ESS7/EST4/ESL4/ELC4
- 25 -
SECTION 3
TEST PROCEDURES
WARNING!
For your safety, and the safety of others:
•
Always test with oil-free air or dry nitrogen only.
•
Always wear eye protection while testing a Regulator.
•
Always perform all of the following test procedures after reassembling a Regulator.
1. Adjust the Test Manifold to the proper pressure shown in
TABLE 4
.
Regulator Model
Gas Service
Manifold Pressure for Testing
Acetylene 30±5
PSIG
EST4, ESL4, ELC4
All Other Gases
200±20 PSIG
ELC4-325-580
Nitrogen 350±20
PSIG
Acetylene & LP Gas
250±20 PSIG
CO
2
& N
2
O 1000±100
PSIG
ESS7
Air, Argon, Hydrogen,
Helium, Nitrogen, Oxygen
2000±100 PSIG
TABLE 4 – Regulator Test Pressures
2. Attach the Regulator to the Manifold connection or test adapter. Start the nut by hand
(do not force), and tighten securely with a wrench to create a seal.
3. Turn the Regulator Adjusting Knob clockwise two or three times until you feel slight
tension being applied to the Adjusting Spring.
4. Slowly open and close the Manifold Valve two or three times to remove contamination
that may cause malfunctions. Leave the Manifold Valve closed.
a. If no flow comes through the Regulator, determine the cause – refer to the
TROUBLESHOOTING CHART
at the end of this section.
5. Turn the Adjusting Knob counterclockwise until it stops, and attach the Test Gun (with a
#52 restricting orifice) to the outlet of the Regulator.
6. Open the Test Manifold Valve and close the Test Gun.
a. Manifold working pressure will appear on the High Pressure Gauge.
b. If the Low Pressure Gauge begins to show pressure building, turn the Test Manifold
off and refer to the
TROUBLESHOOTING CHART
.
7. Use the values in the following
TABLE 5
for all subsequent tests:
Nominal
Delivery
Pressure
A
Pressure Set
for Leak Test
B
Pressure Set for
Creep/Drop Test
C
Drop
Allowance
D
Initial Shut-off
Allowance
15
15 PSIG
10 PSIG
4 PSIG
2 PSIG
40
40 PSIG
10 PSIG
4 PSIG
2 PSIG
80
80 PSIG
10 PSIG
4 PSIG
2 PSIG
125
125 PSIG
20 PSIG
5 PSIG
2.5 PSIG
200
200 PSIG
20 PSIG
5 PSIG
3 PSIG
325
200 PSIG
20 PSIG
5 PSIG
5 PSIG
TABLE 5 –Regulator Test Values