Water treatment.
Consider and ensure adding the appropriate antifreeze or other compounds against freezing and corrosion. If
the water is exceeding the hardness value of 35˚F, you should use water softener.
Note: the person responsible for the heating system should consider and ensure additional heat extension
tank depending from the system.
Warning! It is required to install filter for the incoming water. Failure to do that will cause warranty void of
the water pump.
Warning:
When producing water for sanitary needs, the power output of the radiators will decrease.
First start up (made by the dealer):
Make sure that the heating system is well assembled and equipped with expansion tank which is appropriate
for the safe work of the system. The presence of heat expansion tank in the stove itself, does not guarantee
adequate protection from overheating the water.
- Cconnect the stove to the electrical system and make a cold test.
- Fill up the system thru the inlet valve (recommended pressure 1 bar)
- During the filling bleed the pump manually and open the manual vent /Picture 3/
- These actions must be carried subsequently periodically.
11.Basic instructions for use:
Command board:
ляв дисплей
приемник на сигнал от дистанционното
десен дисплей
зарежзане/резерва
бойлер
Picture 5
1.
Button
turn on or off (hold down for 2 sec.) and for exit during programming mode.
2.
Button
allow access to programming menu.
3.
Button
increasing various settings.
4.
Button
decreasing various settings.
5.
Button
pellet loading / button for reserve. Press once to update the memory of the stove that the
tank is loaded with 15 kg pellets. This will allow the stove to monitor the remaining quantity in the tank.
6.
Button
boiler settings. This button together with the +/- keys controls the secondary circuit e.g.
boiler. The right side of the display shows the temperature of any existing connected storage tank/boiler
(if the boiler sensor is connected). Press the button to see and set the value. If the boiler sensor is not
connected the following image will appear „---
о
С”
First ignition:
The first start up must be done by the dealer.
Consult your dealer when starting up the stove for the first time to calibrate the stove with the pellets
used
The dealer must:
Load / Reserve
Boiler
Right display
Left display
Remote control receiver