Water treatment.  
Consider and ensure adding the appropriate antifreeze or other compounds against freezing and corrosion. If 
the water is exceeding the hardness value of 35˚F, you should use water softener.  

 

Note:  the  person  responsible  for  the  heating  system  should  consider  and  ensure  additional  heat  extension 
tank depending from the system. 
 

Warning! It is required to install filter for the incoming water. Failure to do that will cause warranty void of 
the water pump.  

 

Warning: 
When producing water for sanitary needs, the power output of the radiators will decrease.  

 

First start up (made by the dealer): 

Make sure that the heating system is well assembled and equipped with expansion tank which is appropriate 
for the safe work of the system. The presence of heat expansion tank in the stove itself, does not guarantee 
adequate protection from overheating the water.  
- Cconnect the stove to the electrical system and make a cold test. 
- Fill up the system thru the inlet valve (recommended pressure 1 bar) 
- During the filling bleed the pump manually and open the manual vent /Picture 3/  
- These actions must be carried subsequently periodically.  

11.Basic instructions for use: 

 

Command board: 

 

ляв дисплей

приемник на сигнал от дистанционното

десен дисплей

зарежзане/резерва

бойлер

 

 

Picture 5 

1.

 

Button 

 turn on or off (hold down for 2 sec.) and for exit during programming mode. 

2.

 

Button

 allow access to programming menu. 

3.

 

Button

 increasing various settings. 

4.

 

Button

 decreasing various settings. 

5.

 

Button

 pellet loading / button for reserve. Press once to update the memory of the stove that the 

tank is loaded with 15 kg pellets. This will allow the stove to monitor the remaining quantity in the tank. 

6.

 

Button

  boiler  settings.  This  button  together  with  the  +/-  keys  controls  the  secondary  circuit  e.g. 

boiler. The right side of the display shows the temperature of any existing connected storage tank/boiler 
(if the boiler sensor is connected). Press the button to see and set the value. If the boiler sensor is not 
connected the following image will appear „--- 

о

С” 

 
First ignition: 

 

The first start up must be done by the dealer. 
Consult your dealer when starting up the stove for the first time to calibrate the stove with the pellets 
used  

 

The dealer must:  

Load / Reserve 

Boiler 

Right display 

Left display 

Remote control receiver 

Summary of Contents for Vittoria B Series

Page 1: ...1 Instruction for installation and operation of pellet burning stove with integral water boiler VITTORIA...

Page 2: ...nciple of operation 7 7 Operation 8 8 Safety and detection devices 8 9 Components 8 10 Installation 9 11 Basic instructions for use 11 12 Instructions for use 12 13 Operating modes 12 14 Maintenance 1...

Page 3: ...can be damaged if it is ignited or used with no water in the system The stove is designed to heat water by means of automatic combustion of pellets wood with 6 mm diameter in the combustion chamber If...

Page 4: ...tly and safely The stove must be kept in a room where the temperature is above 0 C Use appropriate anti freeze additives for the water of the system Ensure that the temperature of the return water is...

Page 5: ...s are calculated on the basis of pellets with an heating value of at least 4300 kcal kg and heating loss of the roomof 33 Kcal m h It is also important to consider the position of the stove in the roo...

Page 6: ...has to be reset manually Tank safety thermostat Switches off when the temperature in the stove is too high It stops pellet loading which is causing the stove to shut down It has to be reset manually...

Page 7: ...ing the tank is thru the back of the lid at the rear of the top The fuel pellets is taken from the tank A and via an Archimedes screw powered by electric gear motor is transported to the combustion ch...

Page 8: ...mocouple It is located at the smoke exhaust to measure the temperature It is also controlling the ignition and if the temperature is too high or too low it triggers shut down sequence Stop Flame Hoppe...

Page 9: ...ations in the voltage above 10 can cause malfunction in the appliance unless the appropriate differential switch is installed The electrical system should be in accordance with all local regulations a...

Page 10: ...d into a chimney flue a vertical section of at least 1 5 m will be required complete with a wind guard The vertical duct can be internal or external If the smoke channel is outside it must be insulate...

Page 11: ...ring the filling bleed the pump manually and open the manual vent Picture 3 These actions must be carried subsequently periodically 11 Basic instructions for use Command board Picture 5 1 Button turn...

Page 12: ...date set 12 Instructions for use Feeling the feed screw When the tank for pellets is completely empty this means that the feed screw is also empty Before re igniting the stove you must fill it up fol...

Page 13: ...on the display if is pressed No Prog Prog No 1 one ignition and shutdown per day Prog No2 same as before Prog No3 same as before Use the button to show them in reverse order If you choose the first pr...

Page 14: ...not performed and at least once a season don t make a complete cleaning could cause to poor functionality Any problems resulting from lack of maintenance will immediately void the warranty Daily maint...

Page 15: ...own If the procedures for maintenance are not performed regularly the warranty will void If the stove is used very often it is recommended to clean the smoke channel once every 3 months Warning After...

Page 16: ...rift 8 H2O TEMPALARM Shuts down due to water temperature being higher than 90 C An excessive temperature may occur because of the following system too small ask the DEALER to activate the ECO function...

Page 17: ...stove produce hot air NO Most of the heat is transferred by the water Only small part of the heat is transferred to the room whre the stove is installed by means of radiant heat from the glass It is r...

Page 18: ...18...

Page 19: ...19...

Page 20: ...not kept damages caused during transport inappropriate made heating calculations and project for heating system and installation of the stove there have been made changes in the construction of the st...