background image

3

 

 

 

1.Introduction: 

We  congratulate  you  on  the  excellent  choice!  We  wish  you  many  pleasant  moments  with  your  new 

pellet stove

.  

Do not leave the instructions unread. The installation and exploitation of the pellet stove should be made 

in  accordance  with  different  legal  obligations, which  are  explained  in  this  instruction.  According  to  the  laws  and 
regulations for safety, when using an appliance of such class, the buyer and the user are obliged, with the help of 
this instruction, to inform themselves for the assembling and the right operation of the appliance. 

The  manufacturer  cannot  be  held  liable  for  any  damage  caused  as  a  result  of  incorrect  installation, 

incorrect maintenance procedures and improper use.

 

Your  pellet  stove  is  manufactured  and  tested  in  accordance  with  the  requirements  of  the  following 

standards: EN 14785  EN 60335-1, EN 60335-1-102, EN 55014-1, EN 61000-6-1, EN 61000-6-3 and it is in accordance 
with the approved technical documentation. 

The  appliance  is  not  designed  to  be  used  by  children  and  persons  with  limited  physical,  sensuous  and 

mental  abilities,  or  by  people  with  not  enough  experience  and  knowledge,  except  in  cases  when  they  are 
watched  and  instructed  how  to  work  with  this  type  of  heater,  by  someone  who  is  responsible  for  their  own 
safety 

The pellet stove can be used and maintained only by adults who are familiar with the instruction manual. 

 

2.Safety information: 

 

The pellet stove must never be made to operate without water in the system or at a pressure less than 1 

BAR. The stove can be damaged if it is ignited or used with no water in the system.

 

 

 

The  stove  is  designed  to  heat  water  by  means  of  automatic  combustion  of  pellets  (wood  with  6  mm 
diameter) in the combustion chamber

 

 

If not allowed fuels are used the warranty will void. 

 

Please pay attention during the operation of the appliance children to be kept away from it, because stove  
surface is too hot. Incineration danger! 

 

The  hazard  which  can  come  from  not  following  the  instruction  manual:  direct  contact  with  electrical 
(internal) parts, contact to the flame or with hot surfaces or when using un-allowed fuel. 

 

If there is a malfunction in some part, the stove has safety devices which guarantee that it will automatically 
shut down. The safety devices are activated automatically without any additional intervention.  

 

In order to function correctly, the stove must be installed in accordance with the instructions given here.

 

 

Whilst  functioning,  the  door  must  never  be  opened.  The  combustion  is  fully  automatic  and  requires  no 
manual intervention

 

 

It is absolutely forbidden to use the stove if the glass is damaged or broken. 

 

The handle of the fire door is becoming as hot as the front part of the stove. The heat resisting glove should 
be used when using the handle. 

 

Is is strictly forbidden that any foreign substances be put into the combustion chamber or in the hopper

 

Do not use flammable materials when cleaning the flue outlets.  

 

Before cleaning or maintaining switch of the stove from electrical supply. 

 

Use a vacuum cleaner to clean the fire chamber and hopper only when the stove is cold

 

Never use water to clean the inside parts of the stove. 

 

The glass can be cleaned when cold with a suitable product and a cloth. Do not clean when hot

Summary of Contents for Vittoria B Series

Page 1: ...1 Instruction for installation and operation of pellet burning stove with integral water boiler VITTORIA...

Page 2: ...nciple of operation 7 7 Operation 8 8 Safety and detection devices 8 9 Components 8 10 Installation 9 11 Basic instructions for use 11 12 Instructions for use 12 13 Operating modes 12 14 Maintenance 1...

Page 3: ...can be damaged if it is ignited or used with no water in the system The stove is designed to heat water by means of automatic combustion of pellets wood with 6 mm diameter in the combustion chamber If...

Page 4: ...tly and safely The stove must be kept in a room where the temperature is above 0 C Use appropriate anti freeze additives for the water of the system Ensure that the temperature of the return water is...

Page 5: ...s are calculated on the basis of pellets with an heating value of at least 4300 kcal kg and heating loss of the roomof 33 Kcal m h It is also important to consider the position of the stove in the roo...

Page 6: ...has to be reset manually Tank safety thermostat Switches off when the temperature in the stove is too high It stops pellet loading which is causing the stove to shut down It has to be reset manually...

Page 7: ...ing the tank is thru the back of the lid at the rear of the top The fuel pellets is taken from the tank A and via an Archimedes screw powered by electric gear motor is transported to the combustion ch...

Page 8: ...mocouple It is located at the smoke exhaust to measure the temperature It is also controlling the ignition and if the temperature is too high or too low it triggers shut down sequence Stop Flame Hoppe...

Page 9: ...ations in the voltage above 10 can cause malfunction in the appliance unless the appropriate differential switch is installed The electrical system should be in accordance with all local regulations a...

Page 10: ...d into a chimney flue a vertical section of at least 1 5 m will be required complete with a wind guard The vertical duct can be internal or external If the smoke channel is outside it must be insulate...

Page 11: ...ring the filling bleed the pump manually and open the manual vent Picture 3 These actions must be carried subsequently periodically 11 Basic instructions for use Command board Picture 5 1 Button turn...

Page 12: ...date set 12 Instructions for use Feeling the feed screw When the tank for pellets is completely empty this means that the feed screw is also empty Before re igniting the stove you must fill it up fol...

Page 13: ...on the display if is pressed No Prog Prog No 1 one ignition and shutdown per day Prog No2 same as before Prog No3 same as before Use the button to show them in reverse order If you choose the first pr...

Page 14: ...not performed and at least once a season don t make a complete cleaning could cause to poor functionality Any problems resulting from lack of maintenance will immediately void the warranty Daily maint...

Page 15: ...own If the procedures for maintenance are not performed regularly the warranty will void If the stove is used very often it is recommended to clean the smoke channel once every 3 months Warning After...

Page 16: ...rift 8 H2O TEMPALARM Shuts down due to water temperature being higher than 90 C An excessive temperature may occur because of the following system too small ask the DEALER to activate the ECO function...

Page 17: ...stove produce hot air NO Most of the heat is transferred by the water Only small part of the heat is transferred to the room whre the stove is installed by means of radiant heat from the glass It is r...

Page 18: ...18...

Page 19: ...19...

Page 20: ...not kept damages caused during transport inappropriate made heating calculations and project for heating system and installation of the stove there have been made changes in the construction of the st...

Page 21: ...21 Victoria 05 Ltd 61A Anton Strashimirov Str 5100 Gorna Oryahovitsa Bulgaria phone 359 618 60282 fax 359 618 60200 e mail info v05 bg...