Technical and heating parameters: 
 

Specifications: 

Performance parameters: 

Distance to flammable materials 

Minimum distance, in mm. 
side=400 
back=400 
front=800 

Flue outlet 

Ø 8 cm 

СО emissions [13% О

2

 0,0132 % 

Output flue gas amount 

 12,23g/s 

Working pressure of the water 

1,5 bar 

Maximum test pressure of the water  

3 bar 

Output  flue  gas  temperature  during  nominal 
power  

 108 

°

С  

Heating output 
Nominal heating output 

18 kW 

Radiant heating output 

  2 kW  

Water heating output 

16 kW 

Minimal/Maximal autonomy  

4,9/17,5h 

Water boiler capacity 

  22 l 

Extension tank capacity. 

    8 l 

Water connection dimensions 

3/4" 

Type and size of the fuel 

Pellets Ø 6mm 

Fuel consumption min/max 

 1,2/4,3 kg/h 

Hopper capacity 

25 kg 

Efficiency    

92 ,4% 

Maximal draught 

12 Ра 

Heating capacity 

470 m

Gross weight 

288 kg 

      

The heatable room dimensions are calculated on the basis of pellets with an heating value of at least 4300 kcal/kg and 
heating loss of the room of 33 Kcal/m³ h.

 

It is also important to consider the position of the stove in the room to be heated.

 

It is also very important the capacity and efficiency of the system heaters.   

 

Please note that external devices may cause interference.

 

Warning: work on live components, maintenance and checks must be performed by qualified personnel. (Before 
carrying out any maintenance, disconnect the device from the main power supply).

 

 

 

Electrical characteristics: 

Performance parameters: 

Power supply 

/-10% 50Hz 

ON/OFF switch 

Yes 

Average power consumed

 

120   W 

Average power consumed durring ignition

 

400   W 

Radio control / Remote control frequency

 

Radio waves 2,4 Hz   / infrared 

Main power supply protection

 

Fuse 2А, 250VAC5х20 

Electronic control board protection

 

Fuse 2А, 250VAC5х20 

 

The producer 

reserves the right to make changes to these products to improve their performance with no prior 

warning

 

Summary of Contents for Vittoria B Series

Page 1: ...1 Instruction for installation and operation of pellet burning stove with integral water boiler VITTORIA...

Page 2: ...nciple of operation 7 7 Operation 8 8 Safety and detection devices 8 9 Components 8 10 Installation 9 11 Basic instructions for use 11 12 Instructions for use 12 13 Operating modes 12 14 Maintenance 1...

Page 3: ...can be damaged if it is ignited or used with no water in the system The stove is designed to heat water by means of automatic combustion of pellets wood with 6 mm diameter in the combustion chamber If...

Page 4: ...tly and safely The stove must be kept in a room where the temperature is above 0 C Use appropriate anti freeze additives for the water of the system Ensure that the temperature of the return water is...

Page 5: ...s are calculated on the basis of pellets with an heating value of at least 4300 kcal kg and heating loss of the roomof 33 Kcal m h It is also important to consider the position of the stove in the roo...

Page 6: ...has to be reset manually Tank safety thermostat Switches off when the temperature in the stove is too high It stops pellet loading which is causing the stove to shut down It has to be reset manually...

Page 7: ...ing the tank is thru the back of the lid at the rear of the top The fuel pellets is taken from the tank A and via an Archimedes screw powered by electric gear motor is transported to the combustion ch...

Page 8: ...mocouple It is located at the smoke exhaust to measure the temperature It is also controlling the ignition and if the temperature is too high or too low it triggers shut down sequence Stop Flame Hoppe...

Page 9: ...ations in the voltage above 10 can cause malfunction in the appliance unless the appropriate differential switch is installed The electrical system should be in accordance with all local regulations a...

Page 10: ...d into a chimney flue a vertical section of at least 1 5 m will be required complete with a wind guard The vertical duct can be internal or external If the smoke channel is outside it must be insulate...

Page 11: ...ring the filling bleed the pump manually and open the manual vent Picture 3 These actions must be carried subsequently periodically 11 Basic instructions for use Command board Picture 5 1 Button turn...

Page 12: ...date set 12 Instructions for use Feeling the feed screw When the tank for pellets is completely empty this means that the feed screw is also empty Before re igniting the stove you must fill it up fol...

Page 13: ...on the display if is pressed No Prog Prog No 1 one ignition and shutdown per day Prog No2 same as before Prog No3 same as before Use the button to show them in reverse order If you choose the first pr...

Page 14: ...not performed and at least once a season don t make a complete cleaning could cause to poor functionality Any problems resulting from lack of maintenance will immediately void the warranty Daily maint...

Page 15: ...own If the procedures for maintenance are not performed regularly the warranty will void If the stove is used very often it is recommended to clean the smoke channel once every 3 months Warning After...

Page 16: ...rift 8 H2O TEMPALARM Shuts down due to water temperature being higher than 90 C An excessive temperature may occur because of the following system too small ask the DEALER to activate the ECO function...

Page 17: ...stove produce hot air NO Most of the heat is transferred by the water Only small part of the heat is transferred to the room whre the stove is installed by means of radiant heat from the glass It is r...

Page 18: ...18...

Page 19: ...19...

Page 20: ...not kept damages caused during transport inappropriate made heating calculations and project for heating system and installation of the stove there have been made changes in the construction of the st...

Page 21: ...21 Victoria 05 Ltd 61A Anton Strashimirov Str 5100 Gorna Oryahovitsa Bulgaria phone 359 618 60282 fax 359 618 60200 e mail info v05 bg...

Reviews: