6
4.Safety devices:
-Thermocouple:
Placed at the smoke outlet to detect temperature. Turns the stove on and off and also controls its operation based
on defined parameters.
-Vacuum gauge: (electronic pressure sensor)
Placed on the smoke extractor which detects the vacuum value (compared to the installation enviroment) in the
combustion chamber
-Safety thermostat:
Switches off when the temperature in the stove is too high.
It stops pellet loading which is causing the stove to shut down. It has to be reset manually.
-Tank safety thermostat:
Switches off when the temperature in the stove is too high.
It stops pellet loading which is causing the stove to shut down. It has to be reset manually.
-Fuse:
At the back of the stove are placed 2 fuses. One in the button with socket and one for spare.
5.Electronic circuit board:
Scheme 1
1.smoke extraction motor control
2.inlet air sensor
3.thermoregulator exit water
4.vacuum gauge
5.outlet air sensor
6.power supply
7.ignition unit
8.sensor tº hopper housing
9.thermal limiter tº outlet water
10.hopper
11.pump
12.smoke extraction motor
13.electric wire - black
14.electric wire - black
15.electric wire - brown
16.control panel
17.socket