INSTALLATION
ELECTRICS: Connected with an earthed plug to a 250V~16 amp socket in
accordance with current standards.
HYDRAULICS: The Waste Pump for toilet can only be used with a toilet with
horizontal outlet and equipped with a tank or flushing tap.
The center of the horizontal outlet must be 18cm above the floor in accordance
with European standards
DISCHARGING THE TOILET ONLY
a) Introduce the horizontal bowl into the rubber sleeve of the Waste Pump for
toilet and clamp with the pipe ring supplied – Fig.1
b) Introduce the discharge pipe into the rubber outlet. This shall be 40mm or
32mm in diameter. Clamp with the pipe ring.
CHECK VALVE
If the waste is to be expelled upwards, install the valve vertically as near as
possible to the Waste Pump for toilet.
DISCHARGING WASTE FORM TOILET AND OTHER APPLIANCES
Connect the discharge pipes of the other appliances to the rubber connectors
provided and clamp with the pipe ring – Fig. 2-
For bath or shower wastewater ,check that the slope form the siphon has a
gradient of at least 1 cm per
meter so that the waste flows by gravity to the Waste Pump for toilet.
If other appliance are connected along the discharge line near to the Waste
Pump for toilet, install check
valves on their discharge pipes in order to prevent waste return.
The slope of the horizontal parts of the discharge line must have a gradient of
1 cm per meter.
Fig.1