Electrical Requirements

NOTE: 

The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us.

Remove aluminum filters on hood.

1. 

Position the charcoal filters onto each side of the motor and turn until it locks. Re-install aluminum filters.

2. 

Charcoal filters must be replaced after 120 hours of use (or approximately every 2 to 3 months based on the 

3. 

average of 1 to 2 hours of daily cooking time). Available at your local resellers.

Charcoal Filter Installation

IMPORTANT:

 Observe all governing codes and ordinances. 

(THIS HOOD REQUIRES 120V POWER TO OPERATE PROPERLY)

It is the customer’s responsibility:

To contact a qualified electrical installer.

• 

To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/

• 

NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22. 2 No. 

0-M91 - latest edition** and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that 

the ground path is adequate.

A 120-Volt, 60 Hz, AC-only (USA & Canada standard)

DO NOT ground to a gas pipe.

Check with a qualified electrician if you are not sure that the range hood is properly grounded.

DO NOT have a fuse in the neutral or ground circuit.

IMPORTANT:

 Save this Installation Guide for electrical inspector’s use.

The range hood must be connected with copper wire/plug only.

The range hood should be connected directly to the fused disconnect (or circuit breaker) box through flexible 

armored or non-metallic sheathed copper cable. A U.L. - or C.S.A. - listed strain relief must be provided at each 

end of the power supply cable.

Wire sizes (copper wire only) and connections must conform with the rating of the appliance as specified on 

the  model/serial  rating  label.  Wire  sizes  must  conform  to  the  requirements  of  the  National  Electrical  Code 

ANSI/NFPA  70  —  latest  edition*,  or  CSA  Standards  C22.  1-94,  Canadian  Electrical  Code  Part  1  and  C22. 

2 No.  0-M91 - latest edition** and all local codes and ordinances. A U.L. - or C.S.A. - listed conduit con

-

nector must be provided at each end of the power supply cable (at the range hood and at the junction box).

 

Copies of the standards listed may be obtained from:

*   National Fire Protection Association

Batterymarch Park

Quincy, Massachusetts 02269

**

 

CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

Summary of Contents for 218B2-30

Page 1: ...Hood NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference IMPORTANT Read and save these instructions Rev 1024u 4a VICTORY 218 Series Wall Mounted Range H...

Page 2: ......

Page 3: ...authorities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To...

Page 4: ...o out immediately EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use a...

Page 5: ...tion 9 Installation 10 11 Installation overview 11 USE AND CARE Range hood operations 12 13 Troubleshooting 14 Use and care information 15 Specifications 15 Wiring diagram 16 MAINTENANCE Cleaning repl...

Page 6: ...en ordered together with range hood Parts supplied Hex Key Qty 1 PCS Optional with glass canopy Glass Canopy Screw Qty 4 PCS Optional with glass canopy Qty 6 PCS For sheet rock only A Qty 6 PCS B Qty...

Page 7: ...of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used DO NOT install two elbows tog...

Page 8: ...elbows transitions and caps ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer is used install a long reduce...

Page 9: ...esellers The standard aluminum filters are intended to capture residue from cooking the optional charcoal filters help to purify fumes exhausted from cooking and the optional air diverter redirects fi...

Page 10: ...0 Hz AC only USA Canada standard DO NOT ground to a gas pipe Check with a qualified electrician if you are not sure that the range hood is properly grounded DO NOT have a fuse in the neutral or ground...

Page 11: ...the 1 range hood will be installed Make sure there is proper clear ance within the ceiling or wall for exhaust vent Due to the weight and size of this unit please make sure that 2 the support system o...

Page 12: ...he venting duct between the hood and the ex 4 haust opening either on the ceiling or wall Use alumi num tape to make all joints secure and air tight Connect the range hood to a designated standard out...

Page 13: ...To avoid scratching the chimney extend the upper 8 chimney slowly and carefully to the chimney mount ing bracket and tighten screws as shown in Figure 6 Turn power ON in control panel Check all light...

Page 14: ...tem is running Power Off Delay Digital Timer Indicates the length of time left for delay off function Power Off Delay Timer Indicator Lights up when auto shutdown delay timer function is on Controls A...

Page 15: ...will shut down Adjusting the light Press Light button once to turn on the lights and once again to turn off the lights While the lights are off press and hold Light button for over 3 seconds to dim th...

Page 16: ...t installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the blower is not spinning at all 4 is stuck or is rattl...

Page 17: ...s operating blowers could catch on to hair fingers and loose clothing NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers NEVER leave cooking unattended When frying...

Page 18: ...Page 16 Wiring Diagram Six Speed with Type GU10 Bulb...

Page 19: ...steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless...

Page 20: ...s unplugged or turn OFF breaker Make sure the lights are cool to touch carefully align the arrow on the inner ring with the arrow on the outer ring where it says OPEN with the Inner Ring Opener as sho...

Page 21: ...sumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner produ...

Page 22: ...ng fee of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Ap...

Page 23: ...Your Notes Page 21...

Page 24: ...7272 Buller Ave Burnaby BC V5J4S3 Canada VICTORY range hoods...

Reviews: