background image

Page 9

Advanced Preparations:

Read the entire installation guide and users manual thoroughly, understand instructions and warnings.

1. 

Be familiar with the controls of the range hood by reading through 

2. 

Range Hood Operations

,

 Page 12.

Place the range hood on a flat, stable surface. Connect the range hood to a designated standard outlet (please 

3. 

refer the product label for the suitable voltage of this unit) and verify no debris has entered the vent openings, 

then turn on the range hood. Verify all operations of the range hood by referring to 

Range Hood Operations

Page 12.

Place all supplied parts and required hardware on a flat, stable surface and verify the existence of all supplied 

4. 

parts listed on Page 4.

Carefully remove the white plastic protective coat from the chimney covers and range hood if any.

5. 

WARNING

Severe Injury

Hood may have very shape edges. Please wear 

protective  gloves  if  it  is  necessary  to  remove 

any  parts  for  installing,  cleaning  or  servicing.

Preparation

WARNING

Excessive Weight

Require three or more person to move and 

install this range hood. Spinal or other bodi-

ly injuries could occur if it is not followed.

Preparations:

NOTE: To avoid damage to your hood, prevent debris from 

entering the vent opening.

Determine and mark the center line on the ceiling where the 

1. 

range hood will be installed. Make sure there is proper clear

-

ance within the ceiling or wall for exhaust vent.

Due to the weight and size of this unit, please make sure that 

2. 

the support system or framework being used is stable and 

secure in the ceiling.

Put a thick, protective covering over counter top, cook top or 

3. 

range to protect from damage or dirt. Remove any hazardous 

objects around the area when installing.

Mark the locations of the support mounting bracket holes, 

4. 

vent cutout (if used) and power supply cable cutout on the 

ceiling. Use drill and saber saw or keyhole saw to cut open

-

ings for power supply cable and vent (see 

Venting Methods

 

and 

Electrical requirements

, Pages 7-8).

If  venting  to  the  outside  install  vent  system  (see 

5. 

Venting 

Methods

, Page 7). Use caulking to seal exterior wall or roof 

openings.

Disconnect main electrical supply, prepare and run electrical 

6. 

wiring through ceiling. Leave approximately 12” of electri

-

cal cord hanging from the ceiling. Do not restore power until 

wiring is completed.

Disconnect power cord, remove the aluminum grease filters 

7. 

or stainless steel baffle filter..

Set  aside  the  filters  until  the  range  hood  is  properly  in

-

8. 

stalled.

If the range hood comes with a glass canopy and has not 

9. 

already been mounted to the hood, loosen the four canopy 

screws and washers from the hood top, carefully place the 

canopy on the hood top, and loosely tighten the four canopy 

screws along with washers. DO NOT put excessive pressure 

against the glass.

Summary of Contents for 218B2-30

Page 1: ...Hood NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference IMPORTANT Read and save these instructions Rev 1024u 4a VICTORY 218 Series Wall Mounted Range H...

Page 2: ......

Page 3: ...authorities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To...

Page 4: ...o out immediately EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use a...

Page 5: ...tion 9 Installation 10 11 Installation overview 11 USE AND CARE Range hood operations 12 13 Troubleshooting 14 Use and care information 15 Specifications 15 Wiring diagram 16 MAINTENANCE Cleaning repl...

Page 6: ...en ordered together with range hood Parts supplied Hex Key Qty 1 PCS Optional with glass canopy Glass Canopy Screw Qty 4 PCS Optional with glass canopy Qty 6 PCS For sheet rock only A Qty 6 PCS B Qty...

Page 7: ...of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used DO NOT install two elbows tog...

Page 8: ...elbows transitions and caps ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer is used install a long reduce...

Page 9: ...esellers The standard aluminum filters are intended to capture residue from cooking the optional charcoal filters help to purify fumes exhausted from cooking and the optional air diverter redirects fi...

Page 10: ...0 Hz AC only USA Canada standard DO NOT ground to a gas pipe Check with a qualified electrician if you are not sure that the range hood is properly grounded DO NOT have a fuse in the neutral or ground...

Page 11: ...the 1 range hood will be installed Make sure there is proper clear ance within the ceiling or wall for exhaust vent Due to the weight and size of this unit please make sure that 2 the support system o...

Page 12: ...he venting duct between the hood and the ex 4 haust opening either on the ceiling or wall Use alumi num tape to make all joints secure and air tight Connect the range hood to a designated standard out...

Page 13: ...To avoid scratching the chimney extend the upper 8 chimney slowly and carefully to the chimney mount ing bracket and tighten screws as shown in Figure 6 Turn power ON in control panel Check all light...

Page 14: ...tem is running Power Off Delay Digital Timer Indicates the length of time left for delay off function Power Off Delay Timer Indicator Lights up when auto shutdown delay timer function is on Controls A...

Page 15: ...will shut down Adjusting the light Press Light button once to turn on the lights and once again to turn off the lights While the lights are off press and hold Light button for over 3 seconds to dim th...

Page 16: ...t installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the blower is not spinning at all 4 is stuck or is rattl...

Page 17: ...s operating blowers could catch on to hair fingers and loose clothing NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers NEVER leave cooking unattended When frying...

Page 18: ...Page 16 Wiring Diagram Six Speed with Type GU10 Bulb...

Page 19: ...steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless...

Page 20: ...s unplugged or turn OFF breaker Make sure the lights are cool to touch carefully align the arrow on the inner ring with the arrow on the outer ring where it says OPEN with the Inner Ring Opener as sho...

Page 21: ...sumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner produ...

Page 22: ...ng fee of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Ap...

Page 23: ...Your Notes Page 21...

Page 24: ...7272 Buller Ave Burnaby BC V5J4S3 Canada VICTORY range hoods...

Reviews: