background image

Page 15

Specifications

*

:

Body

Stainless Steel / Tempered Glass

Power Rating

120V/60Hz or 220V/50Hz (Europe standard)

General Input Power

288 W (218W + 2x35W)

Motor Input Power

218 W

Motor Revolution

600 RPM (±10%) to 1800 RPM (±10%)

Levels Of Speed Control

6 Levels

Maximum Airflow

600 CFM

Air Pressure

320 pa

Noise Level (dB / sone)

Approximately 23 / 0.3 to 68 / 7.0 (Lowest to highest Speed)

Motor Type

Dual Chamber Ultra Quiet

Fan Type

Dual Centrifugal / Sirocco

Control Type

6 Speed Electronic Control Panels with LCD Display

Filtration Type

Aluminum Filter with Reversible Handle

Illumination

Halogen 35W or LED 3W Type GU10 120V (220V for Europe) 

Venting Size

Top, 6 inches Round

Interference Protection

Radio Frequency Interference Protected

Use and Care Information

Operations:

Read and understand all instructions and warnings in this manual before operating the appliance. Save these 

• 

instructions for future reference.

Always leave safety grills and filters in place. Without these components, operating blowers could catch on to 

• 

hair, fingers and loose clothing.

NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into blowers.

• 

NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch fire. The risk of 

• 

self combustion is higher when the oil has been used several times.

NEVER cook on “open” flames under the range hood. Check deep-fryers during use: Superheated oil may be 

• 

flammable.

Cleaning:

The saturation of greasy residue in the blower and filters may cause increased inflammability. Keep unit clean 

• 

and free of grease and residue build-up at all times to prevent possible fires.

Filters must be cleaned periodically and free from accumulation of cooking residue (see cleaning instructions 

• 

on Page 17). Old and worn filters must be replaced immediately.

DO NOT operate blowers when filters are removed. Never disassemble parts to clean without proper instruc

-

• 

tions. Disassembly is recommended to be performed by qualified personnel only. Read and understand all 

instructions and warnings in this manual before proceeding.

Specifications

* Subject to change without notice, please contact your local reseller for details.

Summary of Contents for 218B2-30

Page 1: ...Hood NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference IMPORTANT Read and save these instructions Rev 1024u 4a VICTORY 218 Series Wall Mounted Range H...

Page 2: ......

Page 3: ...authorities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To...

Page 4: ...o out immediately EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use a...

Page 5: ...tion 9 Installation 10 11 Installation overview 11 USE AND CARE Range hood operations 12 13 Troubleshooting 14 Use and care information 15 Specifications 15 Wiring diagram 16 MAINTENANCE Cleaning repl...

Page 6: ...en ordered together with range hood Parts supplied Hex Key Qty 1 PCS Optional with glass canopy Glass Canopy Screw Qty 4 PCS Optional with glass canopy Qty 6 PCS For sheet rock only A Qty 6 PCS B Qty...

Page 7: ...of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used DO NOT install two elbows tog...

Page 8: ...elbows transitions and caps ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer is used install a long reduce...

Page 9: ...esellers The standard aluminum filters are intended to capture residue from cooking the optional charcoal filters help to purify fumes exhausted from cooking and the optional air diverter redirects fi...

Page 10: ...0 Hz AC only USA Canada standard DO NOT ground to a gas pipe Check with a qualified electrician if you are not sure that the range hood is properly grounded DO NOT have a fuse in the neutral or ground...

Page 11: ...the 1 range hood will be installed Make sure there is proper clear ance within the ceiling or wall for exhaust vent Due to the weight and size of this unit please make sure that 2 the support system o...

Page 12: ...he venting duct between the hood and the ex 4 haust opening either on the ceiling or wall Use alumi num tape to make all joints secure and air tight Connect the range hood to a designated standard out...

Page 13: ...To avoid scratching the chimney extend the upper 8 chimney slowly and carefully to the chimney mount ing bracket and tighten screws as shown in Figure 6 Turn power ON in control panel Check all light...

Page 14: ...tem is running Power Off Delay Digital Timer Indicates the length of time left for delay off function Power Off Delay Timer Indicator Lights up when auto shutdown delay timer function is on Controls A...

Page 15: ...will shut down Adjusting the light Press Light button once to turn on the lights and once again to turn off the lights While the lights are off press and hold Light button for over 3 seconds to dim th...

Page 16: ...t installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the blower is not spinning at all 4 is stuck or is rattl...

Page 17: ...s operating blowers could catch on to hair fingers and loose clothing NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers NEVER leave cooking unattended When frying...

Page 18: ...Page 16 Wiring Diagram Six Speed with Type GU10 Bulb...

Page 19: ...steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless...

Page 20: ...s unplugged or turn OFF breaker Make sure the lights are cool to touch carefully align the arrow on the inner ring with the arrow on the outer ring where it says OPEN with the Inner Ring Opener as sho...

Page 21: ...sumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner produ...

Page 22: ...ng fee of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Ap...

Page 23: ...Your Notes Page 21...

Page 24: ...7272 Buller Ave Burnaby BC V5J4S3 Canada VICTORY range hoods...

Reviews: