This is a cord-connected unit, and must be connected to its own
dedicated
power supply. Check the dataplate on the
machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.
Note: Do not connect to GFI / GFCI outlets. Connection to that type of outlet can result in product loss due to
unsafe cabinet temperature when GFI device trips from moisture.
Power Cord
This 115 volt model is equipped with a cord and 5-15P or
5-20P plug, depending upon model.
If the power cord becomes damaged, it must be replaced
with the identical cord.
Follow All National and Local Codes
This unit must be grounded. Do not use extension cords
and do not disable or by-pass ground prong on electrical
plug.
Initial Start Up
Plug the power cord into the proper power supply.
The cabinet will soon begin to blow warm air out of the
top area, and cool air will flow from the inside blower.
The cabinet temperature has been set at the factory and
should not need adjustment, however if it was changed,
the standard setting is 0º F.
Cautions
Care must be taken whenever moving or servicing the
unit. The refrigerant is contained in a sealed system, but if
released it may be flammable.
After the cabinet has been installed, leveled, and cleaned
as described above, refer to the following checklist:
Check for proper electrical hook-up.
Cabinet MUST NOT SHARE A RECEPTACLE with another
piece of equipment
Check that all clearances are in line with the
aforementioned guidelines.
Check that cabinet is level.
* NOTE: Once the unit has been started and reaches proper
storage temperatures, it may be loaded with product. For
proper energy efficiency and airflow we recommend a
minimum1” clearance between product and side walls, 4”
clearance between product and ceiling, and 1” clearance
from the bottom of the unit.
ELECTRICAL
5-15P Plug
5-20P Plug