v
Electric Supply
Wiring should be done by a qualified electrician in accordance with local electrical codes.
A separate ground wire must be supplied for all installations.
A properly wired refrigerator or
freezer will assure proper operation. Electrical supply requirements are on the cabinet serial/data
plate. It is recommended that a direct, properly protected line of the proper size wire be installed
from the main supply to your refrigerator or freezer. To assure that the correct voltage is being
supplied, while the refrigerator or freezer is in operation take a voltage reading at the motor-
compressor electrical connections, or as close to the motor-compressor as possible.
All refrigerator or freezer electrical systems are internally grounded.
Temperature Control
Temperature control should be set to maintain a temperature of 38°F (3.3°C) to 40°F (4.4°C) for
refrigerators, and -3°F (-19.4°C) to 3°F (-16.1°C) for freezers.
Temperature Range
-76°F (-60°C) to 185°F (85°C)
Temperature Adjustment
Press Upper Button Quickly to Raise Set Point,
Press Lower Button Quickly to Lower Set Point
To Change Indication
Fahrenheit or Celsius - Press Upper Button 5 Seconds
Forced Defrost
Press Lower Button 5 Seconds
Summary of Contents for FS-1D-S7