Motor
Optional Backdraft Damper
Wrap insulation required
for cold climates
Minimum
8” Ø Duct
36”
typical
Min: 28” Max: 36”
22”
*Min height: 88”
f
rom bottom of duct
to ground when range
height to stove is
28”
Min height: 96”
from bottom of duct
to ground when range
height to stove is
36”
Wall Vent
Roof Vent
• This range hood is factory set for venting through the roof or wall.
•
Duct work can terminate either through the roof or wall. To vent through a wall, a 90° elbow
is needed.
IMPORTANT:
• NEVER exhaust air or terminate
duct work into spaces between
walls, crawl spaces, ceiling, attics or
garages. All exhaust must be vented
to the outside.
•
Use metal/aluminum duct work only.
• Fasten all connections with sheet
metal screws and tape all joints with
certified Aluminum Tape.
•
Use caulking to seal exterior wall or
roof opening around the cap.
• Colder climates require wrapping
insulation around the ducts and
optional blowers.
•
The system must have a Backdraft
Damper.
* Due to different ceiling height configurations, recommended height may not be applicable.
VICTORY range hoods
| HURRICANE
22
VICTORY range hoods
HURRICANE | 23
VENTING METHODS (side view)