To calculate the length of the duct system you require, subtract the equivalent feet for each “Duct piece” (Table
Below) used in the system from the “Recommended maximum run” (Table Below). The longest duct run that
is acceptable (if completely straight) is 50 feet. The number of duct pieces (elbow, transition, etc.) installed in
your duct run will determine the maximum length the duct run can be. Please refer to the example below:
Duct Run Calculation:
Recommended maximum run
6”, 8” or 10” round duct
50 ft
Duct piece deduction
Each 90º elbow used
9 ft
Each 45º elbow used
5 ft
Each 6” to 3/14 x 10” transition
used
7 ft
Side wall cap with damper
7 ft
Roof cap
7 ft
Duct Run Calcuation example:
One roof cap, two 90º elbows, and one 45º elbow
used:
7ft + 9ft + 9ft + 5ft =
30ft
used.
The above duct pieces used are equivalent to 30ft
of a straight duct run. Subtract 30ft from the al
-
lowable 50ft. The remaining distance of 20ft is the
longest that the straight ducting (in addition to the
duct pieces) can be.
Body
Stainless Steel
Power Rating
AC 110-120V, 60Hz (USA & Canada standard)
General Input Power
260 W (Motor 120W +Lamp 4 x 35W) / 450 W (Motor 2x120W
+Lamp 6 x 35W)
Motor Input Power
120 W
Motor Revolution
800 RPM (±10%) to 1300 RPM (±10%)
Levels Of Speed Control
6 Levels
Maximum Airflow
(single motor) 600 CFM / (double motor Model 48) 1000 CFM
Air Pressure
150 Pa (200 Pa Maximum)
Noise Level (dB / sone)
Approximately 35 / 0.7 to 67 / 6.5 (Lowest to Highest Speed)
Motor Type
Single Chamber / Double Chamber
Fan Type
Centrifugal / Sirocco
Control Type
6 speed, Electronic touch sensitive
Filtration Type
Stainless Steel Baffle Filters
Illumination
Models 30, 36, 42: Halogen (4 x 35W) Type GU10 120V, or LED
(4 x 3W) 120V, Dimmable
Model 48: Halogen (6 x 35W) Type GU10 120V, or LED (6 x
3W) 120V, Dimmable
Ducting Size
Top, 6” Round (Models 30, 36, 42) 8” or 10” (Model 48)
Warranty
1 YEAR (parts warranty)
* Subject to change without notice, please contact your local reseller for details.
VICTORY range hoods
| PLANE ISLAND
6
VICTORY range hoods
PLANE ISLAND | 7
CALCULATING DUCT SYSTEM LENGTH
SPECIFICATIONS*