Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include
standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.
Continuous product development may necessitate specification changes and design without notice.
Victory Refrigeration, Inc.
Undercounter Freezers
FOR REMOTE MODELS
– Substitute an “R” for the “S” in suffix. For
example: Model UFS-1D-S7 (self-contained) would be UFS-1D-R7
remote cabinet. Air circulating fans, expansion valve and plasticized
coil are provided. Condensing units not supplied. The following units
are recommended with
1
/
2
” O.D. Suction line,
1
/
4
” O.D. Liquid line.
Dimensional tolerance ±
1
/
4
” Metric dimensions (MM)
REMOTE REFRIGERATION
Cond. Unit
BTUH
Cabinet
Amps
Two Section
1
/
2
H.P.
2160
115/60/1
5.4
Copyright June 2009
Printed in U.S.A. 063009
Crated dim. & wts.
Ht.
Width Depth Cu. Ft. Lbs
One Section
34
1
/
4
56
1
/
4
38
3
/
4
43.1 470
Two Section
34
1
/
4
83
1
/
4
38
3
/
4
63.9 525
CHARACTERISTICS
ONE
TWO
TWO SECTION
SECTION
SECTION
REMOTE
Width, Overall
50
1
/
8
77
1
/
4
60
1
/
2
Depth, Overall (incl. door)
32
7
/
8
32
7
/
8
32
7
/
8
Height, Overall (incl. adj. legs)
34
1
/
2
34
1
/
2
34
1
/
2
Height, Case with
Stainless Steel Top (incl. adj. legs)
35
1
/
4
35
1
/
4
35
1
/
4
Depth, Door(s) Open 90º
55
3
/
4
55
3
/
4
55
3
/
4
Clear Door Opening, Height/Width
23 x 22
23 x 22
23 x 22
Capacity Net (cubic feet)
8.4
18.3
18.3
No. of Door(s)
1
2
2
No. of Shelves
2
4
4
Shelf Area (square feet)
8.5
18.6
18.6
Cabinet Voltage
115/60/1
115/60/1
115/60/1
Feed Wires
2
2
2
Condensing Unit Voltage
115/60/1
115/60/1
------
Condensing Unit Size (HP)
1
/
3
1
/
2
------
Total Amperes
11.6
15.5
------
REMOTE
LEFT END SIDE VIEW
SELF CONTAINED
LEFT END SIDE VIEW
7.75
(197)
15.00
(381)
5.00
(127)
3.00
(76)
MACHINE
COMPARTMENT
15.75
(400)
23.00
(584)
22.25
(565)
2.00
(51)
30.87
(784)
6.00(152)
28.50
(724)
50.12
(1273)
6.00
(152)
8.12
(206)
ELEC.
CONN.
REFRIGERATION
LINE CONN.
CONDENSATE
VAPORIZER
ELEC.
CONN.
DRAIN
CONN.
23.00
(584)
22.25
(565)
22.25
(565)
6.00 (152)
28.50
(724)
77.25
(1962)
8.12
(206)
NOTE:
If cabinet is located
directly against wall an all
around clearance of 2” is
required.
We reserve the right to
change specifications and
product design without
notice. Such revisions do
not entitle the buyer to
corresponding changes,
improvements, additions or
replacements for previously
purchased equipment.