Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include
standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.
Continuous product development may necessitate specification changes and design without notice.
Victory Refrigeration, Inc.
VS-Series Freezers
CHARACTERISTICS
ONE SECTION
TWO SECTION
THREE SECTION
Reach-In
Reach-In
Reach-In
Width, Overall
26
1
/
2
52
1
/
8
77
3
/
4
Depth, Overall (incl. handles)
33
1
/
4
33
1
/
4
33
1
/
4
Height, Overall (incl. adj. legs)
84
84
84
Depth, Open Door 90°
56
3
/
4
56
3
/
4
56
3
/
4
Clear Door Opening, Width
21
1
/
2
21
1
/
2
21
1
/
2
Clear Full Door Opening, Height
54
5
/
8
54
5
/
8
54
5
/
8
Clear Half Door Opening, Height
25
1
/
4
25
1
/
4
25
1
/
4
Capacity Net (cubic feet)
20.4
43.4
66.4
No. of Full Doors
1
2
3
No. of Half Doors
2
4
6
No. of Shelves
3
6
9
Shelf Area (square feet)
17.1
36.0
54.2
Cabinet Voltage
115/60/1
115/60/1
115/60/1
Feed Wires
2
2
3
Condensing Unit Voltage
115/60/1
115/60/1
208-230/60/1
Condensing Unit Size (HP)
1
/
3
1
/
2
3
/
4
Total Amperes
8.5
12.0
12.9
Plug, NEMA
5-15P
5-15P
Hardwire
Crated dim. & wts.
Ht.
Width Depth Cu. Ft.
Lbs.
One Section
84
1
/
4
34
1
/
2
43
82.2
325
Two Section
84
1
/
4
59
43
143.3
530
Three Section
84
1
/
4
86
43
204.4
650
Dimensional tolerance ±
1
/
4
” Metric dimensions (MM)
Copyright June 2009
Printed in U.S.A. 063009
56.00
(1422)
33.25
(844)
31.00
(787)
2.25
(57)
13.88 (352)
6.00 (152)
VSF-1, VSF-2, VSF-3 SIDE VIEW
26.50
(673)
84.00
(2133)
23.88 (606)
TYP. DOOR
TYP. OPENING
VSF-1 FRONT VIEW
26.00
(660)
22.50
(571)
33.25
(844)
VSF-1 TOP VIEW
26.00
(660)
47.75(1212)
33.25
(844)
52.12 (1323)
VSF-2 TOP VIEW
33.25
(844)
77.75(1974)
73.25 (1860)
26.00
(660)
VSF-3 TOP VIEW
52.12 (1323)
21.25
(539)
TYP. OPENING
23.88
(606)
TYP. DOOR
VSF-2 FRONT VIEW
84.00
(2133)
77.75 (1974)
VSF-3 FRONT VIEW
21.25
(539)
TYP. OPENING
23.88
(606)
TYP. DOOR
84.00
(2133)
21.25
(539)
Junction Box
Electric
Connection
Electric
Connection
NOTE:
If cabinet is located
directly against wall an all
around clearance of 2” is
required, and a minimum
clearance of 10” under
ceiling.
We reserve the right to
change specifications and
product design without
notice. Such revisions do
not entitle the buyer to
corresponding changes,
improvements, additions or
replacements for previously
purchased equipment.