5.1. Technical specifications
BatteryProtect
BP-65
BP-100
BP-220
Max. continuous load current
65A
100A
220A
Peak current
250A
600A
600A
Operating voltage range
6 - 35 V
Current consumption
When on: 1.5mA When off or low voltage shutdown: 0.6mA
Alarm output delay
12 seconds
Max. load on alarm output
50mA - short circuit proof
Load disconnect delay
90 seconds (immidiate if triggered by a BMS)
Load reconnect delay
30 seconds
Default thresholds
Disengage: 10.5 V or 21 V Engage: 12 V or 24 V
Operating temperature range
Full load: -40 °C to +40 °C (up to 60% of nominal load at 50 °C)
Connection
M6
M8
M8
Mounting Torque
5 Nm
9 Nm
9 Nm
Weight
0.2 kg 0.5 lbs
0.5 kg 1.1 lbs
0.8 kg 1.8 lbs
Dimensions (hxwxd)
40 x 48 x 106 mm
59 x 42 x 115 mm
62 x 123 x 120 mm
1.6 x 1.9 x 4.2 inch
2.4 x 1.7 x 4.6 inch
2.5 x 4.9 x 4.8 inch
BatteryProtect 12/24V