7
EN
NL
F
R
DE
ES
SE
4.
FLOAT
Keeps the battery at constant voltage and fully charged.
5.
STORAGE
Keeps the battery at reduced constant voltage to limit
gassing and corrosion of the positive plates.
6.
READY (battery fully charged)
The battery is fully charged when the FLOAT or STORAGE
LED is on.
7.
REFRESH
Slow self-discharge is prevented by an automatic weekly
refresh of the battery with a short absorption charge.
3.2 Lithium-ion (LiFePO
₄
) batteries
When charging a Lithium-ion battery, the
Blue Power Charger
uses a specific charging algorithm for Lithium-ion batteries, to
ensure optimum performance.
Select LI-ION with the mode
button.
3.3 When a load is connected to the battery
A load can be applied to the battery while charging. Please note
that the battery will not be charged if the current to the load is
higher than the output current of the charger.
Reconditioning is not possible when a load is connected to the
battery.
3.4 Triggering a new charge cycle
A new charge cycle will start when:
a)
The charger has reached float or storage, and, due to a
load, current increases up to maximum current during more
than four seconds.
b)
The MODE button is pressed during charging.
c)
The AC supply has been disconnected and reconnected.
Summary of Contents for Blue Power 12/15
Page 2: ......
Page 6: ...2 Figure 1 ...
Page 18: ...4 Afbeelding 1 ...
Page 30: ...2 Figure 1 ...
Page 40: ......
Page 44: ...2 Abb 1 ...
Page 58: ...2 Figura 1 ...
Page 70: ...2 Figur 1 ...
Page 79: ...Victron Energy Blue Power Distributor Serial number Version 12 Date May 16 2017 ...