9
EN
NL
F
R
DE
ES
SE
4. Technical specifications
Blue Power IP22 Charger
12V 15/20/30A
24V 8/12/16A
Input voltage range
180-265VAC
Output current, normal mode
15 / 20 / 30A
8 / 12 / 16A
Output current, NIGHT or LOW
7,5 /10 / 15A
4 / 6 / 8A
Efficiency
94%
95%
Standby power consumption
0,5W
Minimum battery voltage
Starts charging from 0V (‘dead battery’)
Charge voltage 'absorption'
Normal: 14,4V
High: 14,7V
Li-ion: 14,2V
Normal: 28,8V
High: 29,4V
Li-ion: 28,4V
Charge voltage 'float'
Normal: 13,8V
High: 13,8V
Li-ion: 13,5V
Normal: 27,6V
High: 27,6V
Li-ion: 27,0V
Charge voltage 'storage'
Normal: 13,2V
High: 13,2V
Li-ion: 13,5V
Normal: 26,4V
High: 26,4V
Li-ion: 27,0V
Min. battery capacity, normal mode
30/40/60Ah
16/24/32Ah
Min. battery capacity, night on low
15/20/30Ah
8/12/16Ah
Temperature compensation
(lead-acid batteries only)
16mV/
°
C
32mV/
°
C
Can be used as power supply
Yes
Back current drain
0,4Ah/month (0,6mA)
Protection
Reverse polarity (fuse) Output short circuit
Over temperature
Cooling
low rpm (silent) fan (12/15 and 24/08 are without fan)
Operating temp. range
-20 to +50°C (full rated output up to 40°C)
Humidity (non condensing)
Max 95%
ENCLOSURE
Battery-connection
Connector 13mm
²
(AWG6)
230V AC-connection
Cable of 1,5 meter with
CEE 7/7, BS 1363 plug (UK) or AS/NZS 3112 plug
Protection category
IP22 (indoor use)
Weight
1,3kg
Dimensions (h x w x d)
235 x 108 x 65mm
STANDARDS
Safety
EN 60335-1, EN 60335-2-29
Emission
EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity
EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Summary of Contents for Blue Power 12/15
Page 2: ......
Page 6: ...2 Figure 1 ...
Page 18: ...4 Afbeelding 1 ...
Page 30: ...2 Figure 1 ...
Page 40: ......
Page 44: ...2 Abb 1 ...
Page 58: ...2 Figura 1 ...
Page 70: ...2 Figur 1 ...
Page 79: ...Victron Energy Blue Power Distributor Serial number Version 12 Date May 16 2017 ...