6
3.5 Configuration of the controller
Fully programmable charge algorithm (see the sof tware page on
our website) and eight preprogrammed charge algorithms,
selectable with a rotary switch:
Pos
Suggested battery type
Absorption
V
Float
V
Equalize
V
@%I
nom
dV/dT
mV/°C
0
Gel Victron long lif e (OPzV)
Gel exide A600 (OPzV)
Gel MK
28,2
27,6
31,8
@8%
-32
1
Gel Victron deep discharge
Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate (OPzS)
Rolls Marine (f looded)
Rolls Solar (f looded)
28,6
27,6
32,2
@8%
-32
2
Default setting
Gel Victron deep discharge
Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate (OPzS)
Rolls Marine (f looded)
Rolls Solar (f looded)
28,8
27,6
32,4
@8%
-32
3
AGM spiral cell
Stationary tubular plate (OPzS)
Rolls AGM
29,4
27,6
33,0
@8%
-32
4
PzS tubular plate traction
batteries or
OPzS batteries
29,8
27,6
33,4
@25%
-32
5
PzS tubular plate traction
batteries or
OPzS batteries
30,2
27,6
33,8
@25%
-32
6
PzS tubular plate traction
batteries or
OPzS batteries
30,6
27,6
34,2
@25%
-32
7
Lithium Iron Phosphate
(LiFePo
4
) batteries
28,4
27,0
n.a.
0
Note: div ide all v alues by two in case of a 12V sy stem and
multiply by two in case of a 48V sy stem.