Number
Name
Setting
01
LOCK SETUP
When set to ON, none of the other settings can be changed. If an attempt is
made to change a setting the word “LOCK” is shown together with the setting
value.
Set to OFF to unlock, so other settings can be changed.
02
BATTERY VOLTAGE
The system battery voltage; choose between a voltage setting or AUTO.
When set to automatic (AUTO), an A will be shown in front of the voltage
setting.
03
BATTERY TYPE
The charge algorithm for a specific battery type; set to FIXED or USER.
When set to FIXED, the rotary switch on the solar charger determines the
battery type.
When set to USER, all charging related settings can be edited.
As soon as any of the charging related settings are changed, this setting will
automatically set to USER.
04
MAXIMUM CURRENT
The maximum charging current.
05
BULK TIME LIMIT
The maximum time the bulk charge stage is allowed to last.
06
ABSORPTION TIME LIMIT
The maximum time the absorption charge stage is allowed to last.
07
ABSORPTION VOLTAGE
The battery voltage at which the solar charger switches from bulk to absorption
stage.
08
FLOAT VOLTAGE
The battery voltage at which the solar charger switches from absorption to
float stage.
09
TEMP COMPENSATION
The temperature compensation coefficient in mV/°C for the whole battery bank
(not per individual battery).
10
LOAD OUTPUT
The Load output operating mode. Possible values: OFF, AUTO (= BatteryLife),
ALT1, ALT2, ON, USER1, USER2
11
LOAD SWITCH HIGH
The high voltage level in case LOAD OUTPUT is set to USER1 or USER2
12
LOAD SWITCH LOW
The low voltage level in case LOAD OUTPUT is set to USER1 or USER2
13
CLEAR HISTORY
Clears the solar charger history
14
FACTORY DEFAULTS
Resets the solar charger settings back to factory defaults.
15
BACKLIGHT INTENSITY
Sets the back-light intensity of the MPPT Control LCD display.
16
BACKLIGHT ALWAYS ON
Determines whether the back-light of the MPPT Control LCD display is always
on.
17
SCROLL SPEED
Determines the scroll speed of the MPPT Control.
18
SELECT TO EDIT
When set to OFF, the MPPT Control first shows the value of a setting and
SELECT has to be pressed to be able to edit the value.
19
AUTO LOCK
When set to ON, the LOCK SETUP setting will be automatically set to ON 2
minutes after a setting has been changed.
20
SOFTWARE VERSION
The software (firmware) version of the MPPT Control.
21
SERIAL NUMBER
The serial number of the MPPT Control.
22
MPPT SOFTWARE
VERSION
The software (firmware) version of the solar charger.
23
MPPT SOFTWARE
VERSION
The serial number of the solar charger.
24
EQUALISATION VOLTAGE
Equalization voltage.
25
EQUALIZE
Initiates a manual equalization.