25
E
N
N
L
F
R
D
E
E
S
A
p
p
en
d
ix
6.4 AC input switch
Maximum AC switch power
(protected by 30 A Thermal Circuit Breaker)
6900 W
Switch-over time inverter to AC input
0 ms
1
Switch-over time AC input to inverter (U batt >10,5 V)
0 ms
1
Detection time AC input fault
4 ms to 20 ms
Trip level mains to inverter
180 VAC
Trip level inverter to mains
187 VAC
Min. - Max. frequency range (50 Hz / 60 Hz)
45 – 55 Hz or 55 – 65 Hz
1
Inverter runs parallel with the AC input.
6.5 Mechanical
12/800
/ 35
12/1200
/ 50
12/1600
/ 70
24/800
/ 16
24/1200
/ 25
24/1600
/ 40
48/1200
/ 12
48/1600
/ 20
12/800
12/1200
12/1600
24/800
24/1200
24/1600
48/1200
48/1600
Cabinet
Aluminum, protectin class IP21
Color
Blue Ral 5012
Dimensions (HxWxD)
375 mm x 215 mm x 115 mm (see App. A)
Weight (kg)
9
10
10
9
10
10
10
10
Battery-connection
cable
1.5 m
1.5m
1.5m
1.5m
1.5m
1.5m
1.5m
1.5m
AC in/out Connection
2 * G-ST18i connector 2,5 mm
2
Start battery
connection
Terminals on printe board (connector suitable for 1mm
2
wires)
External connection:
Remote switch (connector for 3 wire Ø 1mm
2
)
sensing,
Battery temperature sensor (connector for 2 wire Ø 1mm
2
)
remote switch
Alarm: transistor, open collector 66 40mA (connector for 2 wire Ø 0,5 mm
2
)
Serial interface (UTP
connector)
For Phoenix Remote Control
For Mk. 1 with VEConfigure software