4.3 The adaptive charge curve
64 32
60 30
56 28
52 26
48 24
44 22
40 20
C h a rg e c u rre n t
0 %
2 0 %
4 0 %
6 0 %
8 0 %
1 0 0 %
1 2 0 %
T i m e
A m p s
C h a rg e v o lta g e
1 0
1 1
1 2
1 3
1 4
1 5
1 6
T i m e
V o l ts
4-stage charging:
Bulk-mode
: Entered when charger is started. Constant current is applied until the gassing voltage is reached (14.4V resp. 28.8V,
temperature compensated).
Battery Safe Mode:
If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage
has been chosen, the Multi Compact / MultiPlus Compact will prevent damage due to excessive gassing by automatically limiting
the rate of voltage increase once the gassing voltage has been reached.
The Battery Safe Mode is part of the calculated absorption time.
Absorption-mode:
A constant voltage period to fully charge the battery. The absorption time is equal to 20x bulk time or the set
maximum absorption time, whichever comes first.
Float-mode:
Float voltage is applied to keep the battery fully charged and to protect it against self-discharge.
Reduced Float: After one day of Float charge a reduced Float charge is applied. This is 13,2V resp. 26,4V (for 12V and 24V
charger). This will limit water loss to a minimum when the battery is stored for the winter season.
After an adjustable time (default = 7 days) the charger will enter Repeated Absorption-mode for an adjustable time (default =
1 hour).
Bulk hours
1 day
float
7 days reduced
float
Absorption
1 hour Repeated Absorption
7 days
reduced
20 x Bulk-hours or
Max. Absorption time
Battery Safe
mode
64 32
60 30
56 28
52 26
48 24
44 22
40 20
Summary of Contents for Phoenix 12/1200
Page 3: ......
Page 57: ...28 ...
Page 84: ...27 GB NL F D Appendix ...
Page 85: ......
Page 115: ...30 ...
Page 116: ...1 GB NL F D Appendix ...
Page 117: ...2 ...
Page 118: ...3 GB NL F D Appendix ...
Page 119: ...4 ...
Page 120: ...5 GB NL F D Appendix ...
Page 121: ...6 ...
Page 122: ...7 GB NL F D Appendix ...
Page 123: ......