3.2 Small button located to the right of the green 14-Terminal Connector
Block
Short press: WiFi Access point on/off
A single short press toggles the internal WiFi access point on and off. The LED indicates its state:
when the LED blinks green slow, then the built-in Access Point is disabled. when the LED is green and
blinking fast, then the built-in Access Point is enabled.
Long press: reset all network settings to factory defaults
Press and hold the small button for a minimum of four seconds. The LED will stay on for 2 seconds to
indicate that the log press has been recognised; then release the button again.
Ethernet is set back to DHCP
WiFi Access Point is enabled
Remote Console password is disabled
Remote Console on LAN and on VRM is enabled
The same button is available on the Octo GX, button is marked SD_BOOT and available under the lid
at the top.
4. Digital Inputs
The Venus GX has five digital inputs. The channels are accessible via the RJ-12 socket on the side.
This is available for self-wiring by the user/installer.
4.1. Wiring details
The inputs are non-isolated. They operate at 3V3 levels, and can withstand up to 5V input. Each input
has an internal 10k pull-up resistor to 3V3. We recommend wiring it to a potential free relay or
otherwise open collector/optocoupler output.