The drain hose must be arranged beneath the connecting pipe.
The drain hose must not be hunched or twisted.
While wrapping up the drain hose, do not pull it.
The drain hose through the room must be wrapped up by the

thermal insulation materials.

The connecting pipe and the drain hose must be wrapped up by felt
strip. Adiabatic pad should be used at where the pipe contacts
the wall.

NOTE:

1

2

3

ROUTE OF PIPE

If pipe comes out of the right side of the indoor unit, cut part
¡1¡ of  the unit;
If pipe comes out of the lower-right side of the indoor unit, cut
part¡2¡of  the unit;
If pipe comes out of the left side of the indoor unit, cut part¡3¡
of the unit.

Installation of the drain hose

Wiring

2

Open the front grille;
Remove the screw from electrical box cover, pull the
electrical box cover away from the unit and set aside.
Remove the screw from fastener, pull the fastener
away from the unit and set aside.
Connect the cable.
Replace the fastener and electrical box cover.

Indoor unit terminal

Screw

Connecting cable

Diagram

3

4

Drain hose

gaspipe

Liquid pipe

felt

Adiabatic
underlay

NOTE:

NOTICE:

The holes at solid arrow position must be secured to avoid the shake of mounting plate.

When the expansion bolts are used, two holes ( 11 20 or 11 26 )  that the distance

between them is 450mm should be adopted.

Confirm the position of holes, and drill holes on the wall.

40mm

Pipe hole

plumb

fasten string at the central hole

at least 250mm

at least 180mm

at least 140mm

120mm

Center of hole(

)

65mm

Center of hole(

)

65mm

440mm

fasten string at the central hole

at least 80mm

230mm

440mm

at least 120mm

at least 120mm

¦

90mm

plumb

¦

90mm

Pipe hole

The appliance shall be installed in accordance with national wiring regulations.
The appliance must not be installed in the laundry.
The appliance must be installed 2.5m above the floor.
The appliance must be positioned so that the plug is accessible.

For some models whose cooling capacity are above 4600W (17000BTU/h),
an all-pole disconnection device which has at least 3mm separation distance in
all pole and a residual current device(RCD)with the rating of above 10mA shall
be incorporated in the fixed wiring according to the national rule.

Summary of Contents for VS5E3

Page 1: ...SPLIT AIRCONDITIONER INSTALLATION AND REPAIR GUIDE ...

Page 2: ...ns 4 5 Installation of the drain hose Installation of the indoor unit 5 5 Pipe connection Arrangement of the drain hose 5 Wall sealing and Pipe fastening 6 9 Installation of the outdoor unit Wiring Installation of the drain joint 9 9 Joint of the connecting pipe Air exhausting 9 10 Process of flared tube Adding refrigerant 10 Operation test ...

Page 3: ...ALLATION SKETCH 2 Confirm the installation position by the mark of the indoor mounting plate or or or above 155mm above 250mm Above 20mm above 105mm 100mm above 300mm above 500mm above 300mm above 500mm above 500mm Single Split Model OR A B TO INDOOR UNIT above 500mm above 300mm above 300mm Above 500mm above 500mm TO INDOOR UNIT Dual Split Model B TO INDOOR UNIT A above 300mm above 500mm above 300...

Page 4: ...LATION OF THE INDOOR UNIT Securing the mounting plate and drill on the wall 1 Secure the mounting plate The mounting plate should be attached to the structural part of wall post etc fasten string at the central hole 105mm or more from sidewall 155mm or more at least 250mm from sidewall Tapping screw ST4 25 5 mounting plate NOTICE The holes at solid arrow position must be secured to avoid the shake...

Page 5: ...nal Screw Connecting cable Diagram 3 4 Drain hose gaspipe Liquid pipe felt Adiabatic underlay NOTE NOTICE The holes at solid arrow position must be secured to avoid the shake of mounting plate When the expansion bolts are used two holes 11 20 or 11 26 that the distance between them is 450mm should be adopted Confirm the position of holes and drill holes on the wall 40mm Pipe hole plumb fasten stri...

Page 6: ...pipe comes out of the left side of the indoor unit the drain hose must be refitted otherwise water leakage may occur Readjustment methods Interchange the position of drain hose and drain rubber plug Clearance is not allowed after refit it would lead to water leakage Drain rubber plug REFIT OF DRAIN HOSE 5 Pipe Connection Align the centre of joint in line with that of flare and tighten the nut of c...

Page 7: ...Back wiring Sponge Piping cover 2 Loosen the self tapping screws 2 pcs on the fixing clip to loosen the fixing clip 5 Install the maintenance board After the pipes and cable wire are installed please seal the sponge block as per drawing indication 3 Loosen the fixing screw of the wire terminal board pass the power wire and signal wire through the fixing clip Then firmly fix the power wire and sign...

Page 8: ...en Dual Split Model Power source L 2 N2A2B N Connecting cable L 2 N Yellow Green Blue Brown Black Outdoor unit terminal Power source L N L Blue Brown Inverter Type Dual Split Inverter Type Indoor unit A terminal Indoor unit B terminal Cool only and heat pump type Heat pump type Heat pump type Plug housing 1 Blue Plug housing 2 Plug housing 1 Plug housing 2 Blue 2 N 2 N Yellow Green Indoor unit ter...

Page 9: ...0BTU h 5100W 18000BTU h 2500W 9000BTU h 3500W 12000BTU h R407C series 6800W 24000BTU h 5100W 18000BTU h 3200W 11000BTU h 3500W 12000BTU h R22 series 0 116 0 160 0 312 0 312 2500W 9000BTU h 0 467 0 187 0 124 0 138 0 268 Dual Split Model 25 25 Dual Split Model 25 35 0 302 2000W 7000BTU h 0 121 3200W 11000BTU h 0 121 3300W 11500BTU h R410A series 6800W 24000BTU h 5100W 18000BTU h Notice If the interc...

Page 10: ...cap allen wrench Screw down the cap of both gas shut off valve and liquid shut off valve as well as the nut of service port Use Allen wrench to turn the valve cork of liquid side at 90 counter clockwise and close it after 10 seconds Use soapy water to check the gas leakage especially at all joint If there is no gas leakage please turn the valve cork of liquid side at 90 counter clockwise again Pre...

Page 11: ...ust the air as the above mentioned method Tighten nuts and caps of each valve Service port Manifold gauge Low pressure valve High pressure valve Pressure meter Charging line Adding refrigerant If the connecting pipe is longer than 7 metres add refrigerant as needed Cool only type added amount A Lm 7m 15g m Heat pump type added amount A Lm 7m 50g m A amount of added refrigerant L the length of conn...

Page 12: ...uct to a nearby authorized collection center registered dismantler or recycler while disposing off this product In case of further assistance you may contact nearest authorized service center Or Please see the Company website for more information collection centers etc Visit htpp www servicedelight com ...

Reviews: