![background image](http://html1.mh-extra.com/html/videomed/tac500920k/tac500920k_service-manual_1015571028.webp)
Cabling
28
80028124_030_A – 773701 – 2021-04-29
5.3.5
Crimping coaxial cables RG-58 / RG-6
Before crimping coaxial cables RG-58 and RG-6, make sure you:
–
are using the right cable;
–
have a crimping clamp.
Proceed as follows:
OPERATING TEST
The Installer Technician must carefully check the crimped cables
with a tester to detect their conductivity.
VISUAL INSPECTION
The Installer Technician must carry out a visual check on the
crimped cables, remove the incorrect torsions and twists, as well
as removing any crushed sections or damage occurred during the
crimping stage.
Step
Image
1.
Proceed by stripping the end of the cable,
removing the outer sheath protecting the wires
inside.
The incision to remove the sheath must not be
too deep, to prevent damage to the internal
wires.
2.
Insert the cable inside the plug.
Make sure that the cable inside the plug is
positioned correctly.
3.
Push the cable up to the end of the plug.
4.
Place the plug, with its cable, inside the
crimping clamp.
The distance to be crimped is marked by points
[A] and [B].
5.
Compress the plug until the distance between
points [A] and [B] is closed.
B
A
B
A
Summary of Contents for TAC500920K
Page 1: ...Service Manual Truelink 4 Video Management System ENGLISH en US...
Page 2: ...This page is intentionally blank...
Page 6: ...Truelink 4 6 80028124_030_A 773701 2021 04 29 This page is intentionally blank...
Page 113: ...This page is intentionally blank...
Page 114: ...80028124_030_A 773701 2021 04 29...