If the problem persists, increase the PLY (play) Advanced Parameter
by five (5) seconds, but be sure that the REW (rewind) parameter
value is equal to or greater than PLY and that both are less than the
FFD (fast forward) parameter.
Error 9 also displays if a search is in progress but is terminated early
by pressing a Transport key or turning the Jog/Shuttle.
10 VCR number not available
During VCR Configuration, a VCR number that is not defined in Edit
Suite was entered.
The VCR table number will be changed automatically to table 001. If
table 001 is not the table you want to use, return to the VCR field and
enter one of the table numbers from Appendix A.
11 VCR table corrupt
The selected VCR table number is not usable, Edit Suite's memory
has become corrupt, or there is a problem with the LCD.
Unplug then reconnect power to Edit Suite to reset its memory. If the
error persists, retype the VCR number for each VCR. If this does not
fix the problem, select a different VCR table number from Appendix
A.
If there are garbage characters on the LCD, the LCD connection may
be loose. If this occurs, unplug then reconnect power to Edit Suite. If
the display still shows garbage, contact your dealer or Videonics to
have the unit repaired.
12 EDL full
An attempt to create or copy an event was done, but there are not
enough empty events in the EDL to complete the create/copy.
The maximum number of events in the EDL is 250. If you need more
than 250 events and have access to a computer, use the Setup/Export
function to save the EDL on a computer, then delete the existing EDL
via the Setup/EDL function. If you do not have access to a computer,
you will have to delete some events before new events can be created.