22 Invalid ED#
The EDL number entered in the GO TO function ([GO TO]+[OK])
does not exist in the EDL.
If you know the EDL number, try the GO TO function again.
Otherwise, use the up/down arrow keys to search through the EDL
for the event.
23 Insert not available
An INS (insert) event is specified, but the VCRR configuration
indicates that the record VCR cannot do inserts.
If the record VCR can do inserts, change the INS parameter in
SETUP/CONFIG/VCRR from 0 to 1. If the record VCR cannot do
inserts, delete the INS Events from the EDL.
24 Split not available
A SPLT (split insert) event is specified, but the VCRR configuration
indicates that the record VCR cannot do split inserts.
If the record VCR can do split inserts, change the SPLT parameter in
SETUP/CONFIG/VCRR from 0 to 1. Also ensure that the INS
(insert) parameter is set to 1. If the record VCR cannot do split
inserts, delete the SPLT Events from the EDL.
Error Message Display Format
A Setup parameter–MSGS–determines whether error messages will display message numbers only or
message numbers and message text. The following are example of both choices.