Installation Instructions

2

4.

1.

3.

5.

 3 (M4 x 30mm CSK Philips)

6.

 1 (M3 x 6mm)

2.

Magnet holder

 2 (M4 x 30mm CSK Philips)

Flat surface

Colour

Connections

Tamper

Relay

Mandatory

12/24V 
AC/DC 

Exit

NO

C

NC

Transistor

G

NO

NC

Do not apply any voltage to the CODIX BUS.

Red

Black

White

Yellow

Grey

Green

Blue

Orange

Brown

Violet

Pink

Dipswitch

DG/WS/0002  IS

-01

12/24V

(AC/DC)
(CA/CC)

Terminal Connections

Colour

Connections

GND

Black

Violet

Grey

DATA

+9V

Summary of Contents for INOX99 Series

Page 1: ...ime The unit also includes an input to trigger the relay from a push to exit button Both audible and visual indication is standard indicating that a code is correct or incorrect while also helping to navigate through the programming menu Technical Characteristics Codes 99 User Codes 1 8 digits Relays Outputs 1 Relay R1 2A 24v AC DC 1 Transistor Output T1 Ic max 800mA Vceo max 30v Relay Output Time...

Page 2: ...t surface Colour Connections Tamper Relay Mandatory 12 24V AC DC Exit NO C NC Transistor G NO NC Do not apply any voltage to the CODIX BUS Red Black White Yellow Grey Green Blue Orange Brown Violet Pink Dipswitch DG WS 0002 IS 01 12 24V AC DC CA CC Terminal Connections Colour Connections GND Black Violet Grey DATA 9V ...

Page 3: ...CC Black Red White Yellow Grey Green Blue Orange Brown Voilet Pink 12v 24v AC Wiring Diagram IN4002 100nF PTE Normally Open 12 24 DC PSU 12 24 AC PSU DG WS 0002 IS 01 12 24V AC DC CA CC Black Red White Yellow Grey Green Blue Orange Brown Voilet Pink PTE Normally Open ...

Page 4: ...4 EX5 Using Transistor Output With a Art 506 Relay 12v dc DG WS 0002 IS 01 12 24V AC DC CA CC Black Red White Yellow Grey Green Blue Orange Brown Voilet Pink 12 DC PSU ...

Page 5: ...er 00 if latch mode required Press A Press B to exit programming Delete a User Code Press 9 Enter user number 01 99 to delete Press A Press B to exit programming Delete All Codes Press 8 Press A Press B to exit programming Press 99 5 EX5 More codes Yes No Enter Master Code Factory Default 000 Followed by B Enter Master Code Factory Default 000 Followed by B More outputs Yes No More codes Yes No En...

Page 6: ... Keypad is not accepting default master code 000 1 Perform master code reset Keypad no longer accepts user code 1 Check master code has been changed from the default 2 Check back EMF protection across lock release Keypad accepts user code but no longer releases lock 1 Check the correct relay output is assigned to user code 2 Check all push to exit buttons are normally open 3 Check for continuity a...

Page 7: ...7 EX5 ...