background image

VIDEX VproX-100 

(2 DOOR, 100 KEY SYSTEM) 

 

1

DESCRIPTION

 

The 

Vprox

 

100

 is an advanced access control system based upon the VIDEX unique 

Coded Key giving over 4 billion combinations. The system will operate and control two 
independent doors and store up to 100 contact keys or proximity Tag or Card, each door 
can also have an additional reader. Connections from the reader to the control equipment 
can be made using un-shielded 5 core cable up to a distance of 200 meters, or a 
maximum resistance of 10 Ohms. 
 
Push to exit switches at each door will operate the associated relay in the control unit for 
the programmed entry/exit time. 
 
Security against sabotage, is maintained by having the VproX control equipment remote  
from the reader heads. Should un-stored or un-qualified keys attempt to operate the 
system, the control unit will disable all readers after every 5 attempts, the duration of the 
readers disable time will increase if further attempts are made. 
 
The control equipment has an LED display that confirms all data in programming mode, 
and displays the key number when in the stand by mode 

(when key inserted).

 

The system has 4 push buttons for programming and modifying the information. Using 
these buttons it is possible to : 
 
 

Program a Master code to access the programming menu. 

 

Program up to 100 unique keys or Tags with door access options. 

 

To modify the settings and parameters of a stored key.  

 

Delete one or more keys or Tags. 

 

Program each door relay time 

(1 to 99 seconds) 

 

INITIALISATION

 

When the installation has been completed 

(carried out in accordance with the supplied 

wiring diagram)

, the system can be powered up and programmed following the VproX 

100 Programming FLOW CHART, on completion the VproX 100 is ready for use. 

NOTE:

 we suggest to separate the Mains lines 

(lift, electricity, electric lock, etc.)

 from 

the readers connection line 

(at least 10 cm. far or use shielded cable for it)

 to avoid 

electrostatic discharge and magnetic influence which could give control problems to 
the CPUs present on the system. 
 

OPERATION

 

In stand by mode the DISPLAY shows “--”, when a stored key is inserted at any of the 
reader heads the display will show the key number and which door is being operated 
(decimal point position). When a stored key is inserted at any of the readers, the readers 
LED’s will display green and a sharp “beep” will be emitted. If the key is not 
programmed the Display will show nothing and the readers LED’s will display Red and a 
low “beep” will be emitted 
To operate relay 1 for the programmed time 

(door open)

 a n/o switch or short across 

terminal “S1” to ground is required. 
To operate relay 2 for the programmed time 

(door open)

 a n/o switch or short across 

terminal “S2” to ground is required. 

VP100

Summary of Contents for VproX-100

Page 1: ...o access the programming menu Program up to 100 unique keys or Tags with door access options To modify the settings and parameters of a stored key Delete one or more keys or Tags Program each door relay time 1 to 99 seconds INITIALISATION When the installation has been completed carried out in accordance with the supplied wiring diagram the system can be powered up and programmed following the Vpr...

Page 2: ...umber of the 1st free location if available press enter to confirm or select another number by pressing the up arrow keys NOTE If when you press enter you hear a long beep that number is already taken and you must choose another number After pressing enter you may select using the up arrow keys which door the key has access to Default both doors on The doors are indicated by the decimal points on ...

Page 3: ...3 VP100 ...

Page 4: ...1 Normally closed contact Door one C1 Common contact Door one NO2 Normally open contact Door two NC2 Normally closed contact Door two C2 Common contact Door two LG1 Green LED s Door one LR1 Red LED s Door one RK1 Serial data Door one Negative Door one LG2 Green LED s Door two LR2 Red LED s Door two RK2 Serial data Door two Negative Door two Technical Specification Storage capacity 100 keys or Tags...

Page 5: ... CPU with both the Read head connected and disconnected The LED s on the read head are on but do not change state when a key is presented Check terminal RK1 2 for continuity and possible shorts to other wires Reader head is going green when a key or Tag is inserted but the door is not opening Check the relay is operating on the CPU If the relay is operating Check with a volt meter the voltage acro...

Page 6: ...6 VP100 ...

Page 7: ...7 VP100 ...

Reviews: