Bedlift Electrical Installation
Service: 1-866-821-2647
Offi ce: 1-800-210-0141
www�storevertical�com
Page 1
Machine Name - Manual Name
2014Master-ElectricalConnection4-R-Apr2015.indd
SAFETY
R-Series Bedlift Electrical Installation
Locate a customer-supplied outlet near the Bedlift system� Power supplied to this outlet should be on a
dedicated/isolated* circuit
(with an equal or less than 16A circuit breaker)
, including a dedicated/isolated
ground wire to the distribution source�
This circuit should match the electrical specifi cations of the Bedlift�
Plug-in installation considerations: Power supply cord must NOT run through walls, ceilings, fl oors and simi-
lar openings in the building structure� Be sure to take measures to prevent physical damage to the power
supply cord� This includes proper routing of the power supply cord and provision for receptacle (socket
outlet) within reach of electrical cord length�
6ft (1�8m) electrical cord is supplied with Bedlift machine� Bedlift can be hardwired by a certifi ed electrician�
*Note: “Dedicated/isolated” is defi ned as separate hot, neutral and ground wires from the customer distribution source/breaker panel to the
Bedlift junction box/receptacle� To avoid electrical interference, systems must never share wires with any external equipment�
Electrical cord from rear of front-load Bedlift
electrical box to customer supplied outlet�
Model
120V, 60 Hz
240V, 50Hz/60 Hz
15 Amp
10 Amp
15 Amp
ST327-45R
X
X
ST427-45R
X
ST527-45R
X
Plug
NEMA 5-15 Type B
Schuko (50Hz)/NEMA 6-15 (60 Hz)