30L/38L SILENT OIL FREE AIR COMPRESSOR                ENG

1) Ensure the power switch is in the off position (See Fig 2). This air compressor has an integrated 
power and pressure switch. When the power is on the pressure switch will automatically start the air 
compressor motor any time the tank pressure drops below the factory set cut-in pressure and stop the 
motor when the tank pressure stops at the factory set cut-out pressure.
2) Open the drain valve to permit air to escape the tank and prevent air pressure build up during the
break-in period (See Fig 3). The drain valve is located at the base of the air tank and is used to drain 
condensation from the tanks at the end of each use. 
3) Plug the power cable into the correct branch circuit receptacle.
4) Pull the power switch to the on position (See Fig 4). The air compressor will start.
5) Run the air compressor for 10 minutes.
6) After 10 minutes, close the drain valve. The tank will fill to cut-out pressure and the air compressor
motor will stop.
7) Push the power switch to the off position and unplug the air compressor.
8) Pull the safety valve and allow to vent until tank pressure is under 0 psi (See Fig 5).The safety valve 
is designed to protect against high pressure by releasing high pressure air from the air tank when its 
factory set pressure is exceeded.

Warning: If the safety release valve vents under normal operating conditions, stop using 

the air compressor immediately. Send your air compressor for service.

9) Open the drain valve to permit air to escape the tank and to drain any moisture or particles from tank. 
When tank is emptied, close drain valve.
10) Air compressor is now ready for first use.

7. Adjusting regulator

This air compressor is provided with a regulator that controls the output pressure. Regulated pressure 
will be equal to or less than tank pressure depending on user setting.
To adjust regulated pressure (See Fig 6):
1) To increase pressure, turn regulator clockwise. Output pressure is displayed on the pressure gauge.
2) To  decrease  pressure,  turn  regulator  counterclockwise. Output  pressure  is  displayed  on  the 
pressure gauge.

Warning:  Too  much  air  pressure  causes  a  hazardous  risk  of  bursting. Check  the 

manufacturer’s  maximum  pressure  rating  for  air  tools and  accessories.  The  regulator  outlet 
pressure must never exceed the maximum pressure rating

.

8. Starting the air compressor

1) Position air compressor on a flat surface or one with an inclination of 10° or less, in a well ventilated
area away from vapors.
2) Ensure the power switch is in the off position.
4) Plug the power cable into the correct grounding receptacle.
5) Ensure drain valve is closed.
6) Ensure air cock is closed.
7) Ensure safety valve is functioning properly by pulling on the valve ring and allow the valve to reset.
8) Attach hose and accessories to air compressor (See Fig 7,8,9).
9) Turn the power switch to on, and verify that the air compressor is functioning. Adjust the air pressure 
the desired level for the accessory as described in adjusting regulator. Verify that the air compressor
motor stops when cut out pressure is reached.

12

Summary of Contents for WD060213010

Page 1: ...Silent oil free air compressor 30L 38L WD060213010 WD060213810...

Page 2: ...e are confident that you will appreciate the quality of the product and you will be entirely satisfied with your purchase Please read carefully the user safety and operating instruction on how to oper...

Page 3: ...WD060213010 WD060213810 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 11 12 13 3...

Page 4: ...drain valve 12 Fixed knob for hand 13 Safety release valve NORMAL ACCESSORIES 1 Quick coupler 2set We recommend that you purchase your accessories from the same store that sold you the air compressor...

Page 5: ...compressor Distractions may cause loss of control of the tools which may cause injury to bystanders e Never engage in horseplay with the air compressor Respect the air compressor as a working impleme...

Page 6: ...tions solvents or sharp objects Keep air hose away from heat oil sharp edges or moving parts Replace damaged hoses immediately Damaged hoses can burst or whip around work area m Only use hoses with a...

Page 7: ...cts on top or next to air compressor Locate air compressor at least 30 cm 12 in away from all obstructions Restricting any of the air compressor s ventilation openings can cause overheating and could...

Page 8: ...ildren and other personnel unfamiliar with air compressor operation When not in use the tool should be disconnected and stored in a dry place Vent the air tank Keep out of reach of children Lock the s...

Page 9: ...the cable is the grounding wire Never connect the green and yellow or green for 120V wire to a live terminal IMPORTANT NOTE Be sure the supply is the same as the voltage and frequency given on the rat...

Page 10: ...700 min 1400 min Tank volume 30L 30L Max work pressure 8bar 116psi 8bar 116psi Air flow 224L min 7 9CFM 184L min 6 5CFM Protection class I I Machine weight 25 5Kg 25 5Kg Model WD060213810 Rated voltag...

Page 11: ...combustible vapors If the air compressor is being used to operate a sprayer do not place near the spray area 4 Power requirements This air compressor is designed to operate on a properly grounded 110...

Page 12: ...compressor for service 9 Open the drain valve to permit air to escape the tank and to drain any moisture or particles from tank When tank is emptied close drain valve 10 Air compressor is now ready f...

Page 13: ...been drained close the drain valve by clockwise The air compressor can now be stored MAINTENANCE Your air compressor requires periodic maintenance in order to keep your air compressor in peak conditio...

Page 14: ...Contact an authorized service center Air leaks from safety valve Defective safety valve Operate safety valve manually by pulling on ring If valve still leaks it must be replaced Knocking noise Defect...

Page 15: ...circuit breaker tripped Check fuse box for blown fuse and replace as necessary Reset circuit breaker Do not use a fuse or circuit breaker with higher rating than that specified for your particular br...

Page 16: ...30L 38L SILENT OIL FREE AIR COMPRESSOR ENG EXPLOSIVE VIEW 1 2 3 4 5 6 7 11 12 13 14 15 16 17 18 19 20 21 8 9 10 22 23 25 26 27 28 29 30 31 24 16...

Page 17: ...sor 1 20 Screw 1 5 Pressure switch 1 21 Fixing knob of handle 2 6 Pipe joint 1 22 Check valve 1 7 Pipe 1 23 Bolt 2 8 Safety valve 1 24 Air tank 1 9 Pressure regulator knob 1 25 Nut 2 10 Air cock 2 26...

Page 18: ...18 WD060213010 WD060213810...

Page 19: ...19 WD060213010 WD060213810...

Page 20: ...MADE IN CHINA Copyright WIDO Machinery Co Ltd All rights reserved www widopt com...

Reviews: