background image

30L/38L SILENT OIL FREE AIR COMPRESSOR                ENG

stop  using  it  immediately and contact  your  local service center.  There  is a risk  of bursting  if the  air 
compressor is damaged.

d) Before each use inspect air compressor for signs of leaks or damage. If leaks are found in 
the  air  compressor pump, air  tanks  or  tubing,  replace  air  compressor immediately.

Never 

attempt repair leaks, weld or make modifications to the air tank or other fluid confining parts as there is 
a risk of bursting.

e) Never operate the air compressor without the safety valve. Verify operation of the safety 
valve on a daily basis. Do not use the safety valve for complete tank drainage. 

The safety valve is 

designed to relieve tank pressure to reduce the risk of bursting.

f) Never  operate  air  compressor without  all  guards  and other  safety  features  in  place  and 
performing intended function. 

If maintenance or servicing requires removal of guard or safety feature, 

be  sure  to  replace  the guard  or  safety  feature  before  resuming  operation  of the  air  compressor.
Replace damaged guards or safety features immediately.

g) Never touch moving parts. 

Do not place any part of your body near air compressor moving parts. 

Do not reach around guards to reduce the risk of injury.

h) Do not operate air compressor without the air filter.

Filters prevent large particles from entering 

the air stream and damaging air compressor internal components.

i) Do not allow particulates such as sawdust to fall into crankcase when crankcase is open for 
inspection.

Particulates in oil may reduce air compressor life.

j) Do  not  use  air  compressor for  unattended  operation.

Always  remain  in  area  when  air 

compressor is operating and turn off air compressor when not in use to reduce the risk of fire.

k)

Never place objects on top or next to air compressor. Locate air compressor at least 30

cm (12 in) away from all obstructions. 

Restricting any of the air compressor’s ventilation openings 

can cause overheating and could cause a fire.

l) Do not operate the air compressor with any power source other than that specified in the 
tool operating/safety instructions. 

Use of alternative power sources may result in malfunctions of the 

air compressor and  the power  source  which  may  lead  to  serious  injury  of  you or  others  in  your 
surroundings.

m) Follow  all  recommendations  for  sizes  of  hoses,  fittings and  other  compressed  air 
accessories. 

Improperly sized fitting or components may result in the risk of injury or property damage.

n) Never move the air compressor by pulling on a hose. 

The air compressor, air fittings and the air 

hose may become damaged and burst.

o) Check air supply lines for restrictions before adjusting tool. 

Air volume is as important as air 

pressure. Restricted air flow will prevent the tools from operating as designed.

p) Never exceed the maximum allowable pressure rating marked on tools and attachments. Do 
not use air compressor to inflate low pressure objects such as toys. 

Exceeding  the maximum 

recommended pressure of tools and attachments can cause them to burst. The correct pressure is the 
lowest pressure hat will do the job.

q) Drain condensate from air tanks daily with drain valve.

Draining water from the air compressor

reduces the risk of air tank corrosion. Corroded air tanks increase the risk of bursting.

r) Stop the air compressor, drain air tanks and allow it to cool before making adjustments, 
moving the air compressor, leaving the work area, performing maintenance or storing the air 
compressor.

Such precautionary safety measures reduce a risk of injury.

s) Do  not  modify  this  air  compressor or  operate  air  compressor at  pressures  or  speeds 
greater  than  designed

. Any alteration  or  modification  is  a  misuse  and  may  result in  a  dangerous 

7

Summary of Contents for WD060213010

Page 1: ...Silent oil free air compressor 30L 38L WD060213010 WD060213810...

Page 2: ...e are confident that you will appreciate the quality of the product and you will be entirely satisfied with your purchase Please read carefully the user safety and operating instruction on how to oper...

Page 3: ...WD060213010 WD060213810 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 11 12 13 3...

Page 4: ...drain valve 12 Fixed knob for hand 13 Safety release valve NORMAL ACCESSORIES 1 Quick coupler 2set We recommend that you purchase your accessories from the same store that sold you the air compressor...

Page 5: ...compressor Distractions may cause loss of control of the tools which may cause injury to bystanders e Never engage in horseplay with the air compressor Respect the air compressor as a working impleme...

Page 6: ...tions solvents or sharp objects Keep air hose away from heat oil sharp edges or moving parts Replace damaged hoses immediately Damaged hoses can burst or whip around work area m Only use hoses with a...

Page 7: ...cts on top or next to air compressor Locate air compressor at least 30 cm 12 in away from all obstructions Restricting any of the air compressor s ventilation openings can cause overheating and could...

Page 8: ...ildren and other personnel unfamiliar with air compressor operation When not in use the tool should be disconnected and stored in a dry place Vent the air tank Keep out of reach of children Lock the s...

Page 9: ...the cable is the grounding wire Never connect the green and yellow or green for 120V wire to a live terminal IMPORTANT NOTE Be sure the supply is the same as the voltage and frequency given on the rat...

Page 10: ...700 min 1400 min Tank volume 30L 30L Max work pressure 8bar 116psi 8bar 116psi Air flow 224L min 7 9CFM 184L min 6 5CFM Protection class I I Machine weight 25 5Kg 25 5Kg Model WD060213810 Rated voltag...

Page 11: ...combustible vapors If the air compressor is being used to operate a sprayer do not place near the spray area 4 Power requirements This air compressor is designed to operate on a properly grounded 110...

Page 12: ...compressor for service 9 Open the drain valve to permit air to escape the tank and to drain any moisture or particles from tank When tank is emptied close drain valve 10 Air compressor is now ready f...

Page 13: ...been drained close the drain valve by clockwise The air compressor can now be stored MAINTENANCE Your air compressor requires periodic maintenance in order to keep your air compressor in peak conditio...

Page 14: ...Contact an authorized service center Air leaks from safety valve Defective safety valve Operate safety valve manually by pulling on ring If valve still leaks it must be replaced Knocking noise Defect...

Page 15: ...circuit breaker tripped Check fuse box for blown fuse and replace as necessary Reset circuit breaker Do not use a fuse or circuit breaker with higher rating than that specified for your particular br...

Page 16: ...30L 38L SILENT OIL FREE AIR COMPRESSOR ENG EXPLOSIVE VIEW 1 2 3 4 5 6 7 11 12 13 14 15 16 17 18 19 20 21 8 9 10 22 23 25 26 27 28 29 30 31 24 16...

Page 17: ...sor 1 20 Screw 1 5 Pressure switch 1 21 Fixing knob of handle 2 6 Pipe joint 1 22 Check valve 1 7 Pipe 1 23 Bolt 2 8 Safety valve 1 24 Air tank 1 9 Pressure regulator knob 1 25 Nut 2 10 Air cock 2 26...

Page 18: ...18 WD060213010 WD060213810...

Page 19: ...19 WD060213010 WD060213810...

Page 20: ...MADE IN CHINA Copyright WIDO Machinery Co Ltd All rights reserved www widopt com...

Reviews: