background image

30L/38L SILENT OIL FREE AIR COMPRESSOR                ENG

at any time.
i)

Always turn off the motor when not in use and before moving air compressor.

Stopping the 

motor prevents unintentional starting of the air compressor.

GROUNDING INSTRUCTIONS

This air compressor should be grounded while in use to protect the operator from electric shock. The air 
compressor is equipped with a three-core cable and grounding type plug to fit the proper grounding 
type receptacle. The green and yellow or green (for 120V) conductor in the cable is the grounding wire. 
Never connect the green and yellow or green (for 120V) wire to a live terminal.

IMPORTANT NOTE

Be sure the supply is the same as the voltage and frequency given on the rating plate. 
Remove the main plug from socket before carrying out any adjustment or servicing.

SYMBOLS

To reduce the risk of injury, user must read instruction manual

Warning

      

Wear ear protection

Wear eye protection

Wear dust mask

Do not disassembly on working condition

Do not direct air stream at people or animals

Burns risk

Waste electrical products should not be disposed of with household waste. Please recycle 
where facilities exist. Check with your Local Authority or retailer for recycling advice

      

      

9

Summary of Contents for WD060213010

Page 1: ...Silent oil free air compressor 30L 38L WD060213010 WD060213810...

Page 2: ...e are confident that you will appreciate the quality of the product and you will be entirely satisfied with your purchase Please read carefully the user safety and operating instruction on how to oper...

Page 3: ...WD060213010 WD060213810 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 11 12 13 3...

Page 4: ...drain valve 12 Fixed knob for hand 13 Safety release valve NORMAL ACCESSORIES 1 Quick coupler 2set We recommend that you purchase your accessories from the same store that sold you the air compressor...

Page 5: ...compressor Distractions may cause loss of control of the tools which may cause injury to bystanders e Never engage in horseplay with the air compressor Respect the air compressor as a working impleme...

Page 6: ...tions solvents or sharp objects Keep air hose away from heat oil sharp edges or moving parts Replace damaged hoses immediately Damaged hoses can burst or whip around work area m Only use hoses with a...

Page 7: ...cts on top or next to air compressor Locate air compressor at least 30 cm 12 in away from all obstructions Restricting any of the air compressor s ventilation openings can cause overheating and could...

Page 8: ...ildren and other personnel unfamiliar with air compressor operation When not in use the tool should be disconnected and stored in a dry place Vent the air tank Keep out of reach of children Lock the s...

Page 9: ...the cable is the grounding wire Never connect the green and yellow or green for 120V wire to a live terminal IMPORTANT NOTE Be sure the supply is the same as the voltage and frequency given on the rat...

Page 10: ...700 min 1400 min Tank volume 30L 30L Max work pressure 8bar 116psi 8bar 116psi Air flow 224L min 7 9CFM 184L min 6 5CFM Protection class I I Machine weight 25 5Kg 25 5Kg Model WD060213810 Rated voltag...

Page 11: ...combustible vapors If the air compressor is being used to operate a sprayer do not place near the spray area 4 Power requirements This air compressor is designed to operate on a properly grounded 110...

Page 12: ...compressor for service 9 Open the drain valve to permit air to escape the tank and to drain any moisture or particles from tank When tank is emptied close drain valve 10 Air compressor is now ready f...

Page 13: ...been drained close the drain valve by clockwise The air compressor can now be stored MAINTENANCE Your air compressor requires periodic maintenance in order to keep your air compressor in peak conditio...

Page 14: ...Contact an authorized service center Air leaks from safety valve Defective safety valve Operate safety valve manually by pulling on ring If valve still leaks it must be replaced Knocking noise Defect...

Page 15: ...circuit breaker tripped Check fuse box for blown fuse and replace as necessary Reset circuit breaker Do not use a fuse or circuit breaker with higher rating than that specified for your particular br...

Page 16: ...30L 38L SILENT OIL FREE AIR COMPRESSOR ENG EXPLOSIVE VIEW 1 2 3 4 5 6 7 11 12 13 14 15 16 17 18 19 20 21 8 9 10 22 23 25 26 27 28 29 30 31 24 16...

Page 17: ...sor 1 20 Screw 1 5 Pressure switch 1 21 Fixing knob of handle 2 6 Pipe joint 1 22 Check valve 1 7 Pipe 1 23 Bolt 2 8 Safety valve 1 24 Air tank 1 9 Pressure regulator knob 1 25 Nut 2 10 Air cock 2 26...

Page 18: ...18 WD060213010 WD060213810...

Page 19: ...19 WD060213010 WD060213810...

Page 20: ...MADE IN CHINA Copyright WIDO Machinery Co Ltd All rights reserved www widopt com...

Reviews: