Push union nut, sliding ring and seal onto the drain elbow.

Screw the union nut on the drain unit.

Maintain an insertion depth of at least 15 mm!

Turn the drain at the joint until the required position has been
reached.

Push wastewater pipe in the drain elbow.

3.2.6

Connecting the inlet

Proceed as follows to connect the water inlet to the drain unit:

Requirements:

n

A connection set (e. g. the pipe interrupter set) is available.

n

A pipe interrupter is installed in the supply pipeline.

n

Overflow and drain are mounted.

n

Overflow and drain are connected.

n

The connection to the wastewater system has been made.

Remove the union nut of the connection elbow from the drain unit
and remove connection elbow.

Ø50

Ø40

Handling

Multiplex Trio F drain/overflow functional unit

18 from  25

Summary of Contents for 6145.5

Page 1: ...for water inlet through the drain unit Model Year built 6145 5 from 06 2015 en_INT Multiplex Trio F drain overflow functional unit Instructions for Use ...

Page 2: ...Multiplex Trio F drain overflow functional unit 2 from 25 ...

Page 3: ...on dimensions 11 3 1 3 Required tools and materials 11 3 2 Assembly 12 3 2 1 Connect and mount pipe interrupter 12 3 2 2 Mounting overflow 14 3 2 3 Mounting the drain 15 3 2 4 Connecting overflow and drain 16 3 2 5 Connecting the wastewater system 17 3 2 6 Connecting the inlet 18 3 2 7 Mounting equipment set 19 3 2 8 Leakage test 20 3 3 Control 20 3 4 Simple maintenance and cleaning pipe 21 3 4 1 ...

Page 4: ...oes not extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs DANGER This symbol warns against possible life threatening injury WARN...

Page 5: ... Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The pertinent national laws stand ards regulations and guidelines as well as other technical guidelines have priority over German European guidelines in this manual The information is not binding for other countrie...

Page 6: ...odour trap for bathtubs with a 52 mm drain hole The inlet flows particularly quietly through the overflow opening The drain overflow is suitable for bathtubs with a middle connection Detailed information regarding all bathtub models and the corre sponding Viega drains overflows can be found in the catalogue or on the Internet 2 2 Product description 2 2 1 Overview The following components are incl...

Page 7: ...l 7 profile seal 8 connection elbow 9 drain elbow 10 union nut 11 sliding ring 12 seal 13 drain unit with odour trap 14 overflow pipe 15 Bowden cable 16 sleeve 17 overflow unit 18 profile seal 19 O ring 20 fixing flange 21 rotatable rosette 22 pipe interrupter casing 23 top of the pipe interrupter 24 pipe interrupter rosette Product information Multiplex Trio F drain overflow functional unit 7 fro...

Page 8: ...480 mm Dimensions and installation depth Ä Chapter 3 1 2 Installation dimensions on page 11 Water seal level 50 mm 2 3 Accessories The accessories shown here are not included in the scope of delivery If required it must be purchased separately Multiplex extension set It is possible to extend the odour trap below the bathtub in the case of bathtubs with a very thick floor The extension set model 61...

Page 9: ...ion If a negative pressure situation should occur when the bathtub is filled there is a possibility that bath water may flow back into the drinking water system To ensure that no bath water flows back into the drinking water system a pipe interrupter must be installed in the pipeline between the shut off fitting and the bathtub inlet The following schematic diagram shows what this should look like...

Page 10: ...is important that the pipe interrupter is mounted vertically in the direction of flow and at least 150 mm above the top edge of the bathtub Observe the local standards and regulations Handling Multiplex Trio F drain overflow functional unit 10 from 25 ...

Page 11: ...ght L 130 370 H 180 370 3 1 3 Required tools and materials The following tools are required for mounting n fine toothed saw n mounting aid included in the scope of delivery n Allen key SW 3 No additional material is required for the complete mounting of the product Tool Material Handling Multiplex Trio F drain overflow functional unit 11 from 25 ...

Page 12: ...If necessary observe the manufacturer s instructions Push the union nut and clamping ring onto the pipe Push Viega plug in seat as far as it will go into the pipe Euro cone connections are not compatible Push the free end of the plug in seat into the connection of the pipe interrupter Using the union nut screw the pipe tightly onto the pipe interrupter Repeat the procedure with the second pipe INF...

Page 13: ...ill holes Screw on pipe interrupter with two crossed slot screws size 4 5 or 5 Encase the pipe interrupter and connection line in mortar Tile the wall Remove protective plug 90 Handling Multiplex Trio F drain overflow functional unit 13 from 25 ...

Page 14: ...en contaminated Insert the rosette into the shaft top 3 2 2 Mounting overflow Proceed as follows to the mounting of the overflow Push the rubber sleeve onto the pipe of the overflow unit The lower edge must be flush with the edge of the overflow pipe Handling Multiplex Trio F drain overflow functional unit 14 from 25 ...

Page 15: ...ange into the overflow unit by hand Pliers or other tools may damage the fixing flange Only turn the fixing flange by hand 3 2 3 Mounting the drain Proceed as follows to mount the drain Place the profile seal in the recess of the drain unit Mount the drain unit with profile seal on the drain opening of the bathtub from below Handling Multiplex Trio F drain overflow functional unit 15 from 25 ...

Page 16: ...e placed on the screw recesses with the holes on the underside 3 2 4 Connecting overflow and drain After the overflow and the drain have been mounted you must connect them both using the overflow pipe Proceed as follows Requirements n The overflow is mounted in the overflow opening n The drain is securely mounted on the base of the bathtub NOTICE Connections where the pipes are not inserted far en...

Page 17: ...on depth of at least 15 mm Push the union nut sliding ring and seal onto the bottom end of the drain elbow Screw the union nut on the drain unit 3 2 5 Connecting the wastewater system Proceed as follows to connect the drain overflow to the wastewater system Requirements n The overflow and drain units are installed on the bathtub n The connection between overflow and drain has been made If the wast...

Page 18: ...oceed as follows to connect the water inlet to the drain unit Requirements n A connection set e g the pipe interrupter set is available n A pipe interrupter is installed in the supply pipeline n Overflow and drain are mounted n Overflow and drain are connected n The connection to the wastewater system has been made Remove the union nut of the connection elbow from the drain unit and remove connect...

Page 19: ...of the screw fitting into the connection elbow Screw in the pipe tight with the union nut onto the connection elbow Place the connection elbow onto the connection of the drain unit and tighten the union nut by hand 3 2 7 Mounting equipment set To avoid damage to the rosette and valve cone only mount the equip ment set after finishing all other work on the building site Proceed as follows Fit the i...

Page 20: ...to the drain by hand Align and push in overflow rosette 3 2 8 Leakage test The leakage test is only carried out as a visual inspection Check drain overflow fitting for visible leaks 3 3 Control The drain overflow are controlled via the rotatable rosette on the over flow Proceed as follows to open or close the drain Handling Multiplex Trio F drain overflow functional unit 20 from 25 ...

Page 21: ...ement dissolver solvents or other acidic cleaning agents Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the rotatable rosette and valve cone Under no circumstances should scouring agent or scratching objects be used Strong stains even around the drain unit and the siphon can be removed using typical household cleaner It should be noted that the cl...

Page 22: ...uring mounting In the case of extensive contamination the insert has to be replaced to ensure the functionality of the pipe interrupter Proceed as follows to clean or replace the insert with the membrane Remove rosette Pull the insert out of the casing using multigrip pliers If there is only a little limescale and contamination rinse the insert carefully Handling Multiplex Trio F drain overflow fu...

Page 23: ...ng of the pipe interrupter vertically from the front Insert the rosette into the shaft top 3 4 3 Cleaning the drain The drain should be cleaned at regular intervals The cleaning interval depends on the use of the tub installation Proceed as follows to clean the drain Handling Multiplex Trio F drain overflow functional unit 23 from 25 ...

Page 24: ...3 Remove inlet element Clean inlet element by holding it under running water Do not use any sharp or pointed objects when cleaning as this could damage the material Loosen the Allen screw of the valve cone with an Allen key size 3 Handling Multiplex Trio F drain overflow functional unit 24 from 25 ...

Page 25: ...intended for the valve cone If necessary clean drain casing with running water and a mild cleaning agent INFO Do not use any abrasive cleaner or pipe cleaner as these can damage the plastic of the drain casing To install follow the same steps in reverse order 3 5 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with va...

Reviews: